Related Experiment Video
Updated: Jul 6, 2026

Quantitative Detection of Trace Explosive Vapors by Programmed Temperature Desorption Gas Chromatography-Electron Capture Detector
Published on: July 25, 2014
Gas flow tracking for electronic pressure control system in gas chromatography under state constraints and
Yulong Nie1, Zheng Yang1, Chenglong He1
1School of Automation Science and Electrical Engineering, Beihang University, Beijing 100191, China.
Abstract:
In gas chromatography (GC) analysis, the gas flow control performance of the Electronic Pressure Control (EPC) system that is responsible for signal analysis and processing, critically determines the reliability and accuracy of analytical results. However, during the gas flow control, unknown hysteresis characteristics, voltage saturation, and state constraints significantly impact control performance. This study addresses the fuzzy adaptive practically finite-time output feedback and signal processing problem for the EPC system in GC, incorporating system state constraints and unknown hysteresis characteristics. First, a modified Prandtl-Ishlinskii model is employed to accurately describe the valve's unknown asymmetric hysteresis. A dynamic model reflecting the actual system, incorporating gas resistance characteristics, is then established. Second, a fuzzy state observer based on a fuzzy logic system (FLS) is designed to estimate unmeasurable system states. Third, considering state constraints and potential computational complexity, a fuzzy adaptive practically finite-time controller is proposed. This controller, built upon the observer, integrates backstepping, dynamic surface control (DSC), and barrier Lyapunov functions (BLF), utilizing filters for smooth processing of virtual signals. System stability is then proven via Lyapunov theory. Finally, experimental verification is performed using both step and dynamic gas flow targets with a newly constructed EPC system. The results demonstrate that the proposed controller achieves precise and stable tracking control of gas flow, even in the presence of unknown hysteresis, state constraints, and voltage saturation.
More Related Videos
Related Concept Videos
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Bioreactor Controls-I
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Gas Chromatography: Sample Injection Systems
Two primary injection methods are used...
Gas Chromatography: Types of Detectors-II
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a column.