Surfactant Depletion Combined with Injurious Ventilation Results in a Reproducible Model of the Acute Respiratory Distress Syndrome (ARDS)
Published on: April 7, 2021
Real-time algorithm-driven ventilation feedback to improve lung-protective ventilation in patients with ARDS
Longxiang Su1, Yingying Yang2, Ye Wang3
1Department of Critical Care Medicine, State Key Laboratory of Complex Severe and Rare Diseases, Peking Union Medical College Hospital, Peking Union Medical College, Chinese Academy of Medical Science, Beijing, China. sulongxiang@vip.163.com.
Background:
Lung-protective ventilation is a cornerstone of modern mechanical ventilation, yet real-world adherence to lung-protective targets remains suboptimal. While previous studies have established the physiological benefits of low tidal volume and driving pressure, clinical implementation is hindered by limited monitoring granularity and lack of real-time actionable feedback. This trial aims to evaluate whether a real-time, cloud-based algorithmic feedback platform can improve lung-protective ventilation delivery and contribute to better clinical outcomes in mechanically ventilated patients with ARDS.
Methods:
This multicentre, parallel-group, open-label randomised controlled trial will enrol 208 adult mechanically ventilated ICU patients with ARDS from nine adult ICUs across tertiary academic hospitals and regional referral centres in multiple provinces and municipalities in mainland China. Participants will be randomly assigned in blocks to receive either standard monitoring (Control group) or real-time respiratory mechanics feedback through a cloud-based platform (Intervention group). The intervention group will receive real-time alerts for lasting 72 h and ventilator reports every 24 h, integrating tidal volume, plateau pressure, driving pressure, mechanical power, and detected patient-ventilator asynchrony events. The primary outcome is the lung-protective ventilation achievement rate, defined as compliance with VT < 8 mL/kg predicted body weight, driving pressure < 15 cmH₂O, plateau pressure < 30 cmH₂O, and mechanical power < 17 J/min during the first 72 h after randomisation. Secondary outcomes include ventilator-free days at day 28, ICU length of stay, ventilator-associated complications, inflammatory biomarkers, clinician satisfaction, and predefined safety outcomes, including severe hypoxemia, severe hypercapnia/acidemia, barotrauma, and hemodynamic instability temporally associated with ventilator adjustments.
Discussion:
This study is, to our knowledge, among the first multicentre randomised controlled trials to evaluate a real-time algorithmic feedback platform designed to enhance lung-protective ventilation. The intervention is designed to provide continuous bedside feedback on ventilation mechanics and may enable more timely and standardised clinical adjustments, with the potential to facilitate lung-protective ventilation delivery. Triaiontl registration ClinicalTrials.gov Identifier NCT07307066 (Registration Date: 2025/12/02).
Related Concept Videos
Ventilatory Modes
There are three ventilatory modes: full support, partial support, and spontaneous. These are described below.
Full Support Modes
Full support modes include controlled mechanical ventilation, continuous mandatory...
Acute Respiratory Failure-V
Ensure that patients are monitored continuously for their response to therapy, including changes in...
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation (NIPPV)
Assessment of Ventilation II: Respiratory Depth and Rhythm
Respiratory depth measures the volume of air inhaled or exhaled during a breath. It can vary from shallow to deep and typically remains consistent when a person is at rest or asleep. Occasionally, individuals will automatically inhale deeply, known as sighing, which inflates the lungs with more air than normal breathing.
To assess respiratory depth, observe the degree of chest excursion or movement: