Integrated Compensatory Responses in a Human Model of Hemorrhage
Published on: November 20, 2016
Real-time personalized hemodynamic responses to enhanced external counterpulsation therapy in post-PCI patients using
Zhibo Wang1,2, Xuanhao Xu1,2, Qi Zhang1,3
1Department of Cardiology, The Eighth Affiliated Hospital of Sun Yat-sen University, Shenzhen, Guangdong 518033, People's Republic of China.
None:
Background and objective.Enhanced external counterpulsation (EECP) has shown promise in facilitating postoperative recovery in patients after percutaneous coronary intervention by improving the hemodynamic environment within the stents. However, understanding of the hemodynamic environment across patient profiles, encompassing geometric features of the stent (e.g., length, diameter, and curvature) and patient demographics (e.g., height, age, and weight), has yet to be fully elucidated.Methods.A multidimensional 0/1D-3D coupled model was developed using clinical data from 18 subjects. This model integrated a 0/1D model for assessing the blood perfusion and pressure in coronary arteries with a 3D model to predict the intricate in-stent hemodynamic environment.Results.The simulation results showed increases in time-averaged wall shear stress (TAWSS), transverse wall shear stress, and oscillatory shear index and a decrease in relative residual time under the effect of EECP. Moreover, TAWSS consistently decreased with increasing length and stent diameter while decreasing with increasing stent curvature.Conclusions.A surrogate model based on polynomial chaos expansion, which provides valuable tools for expedited clinical decision-making, was developed from the numerical results for TAWSS enhancement ratio. This model incorporated both the physiological characteristics of the subjects and the geometric features of the stent.
Related Concept Videos
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment: