Pulsed Field Ablation of Atypical Atrial Flutter in a Patient After Hybrid Ablation of Atrial Fibrillation
Austin Deets1, Muhammad Zaman1, Daniel W Nelson1
1Aurora Cardiovascular and Thoracic Services Aurora Sinai/Aurora St Luke's Medical Centers, Aurora Health Care Milwaukee Wisconsin USA.
Abstract:
After hybrid surgical ablation of atrial fibrillation, a 73-year-old-man underwent pulmonary vein isolation, roof, and anterior mitral line using Farapulse. He developed atypical atrial flutter from reconnection of the anterior mitral line; four "stamps" were applied along the line with immediate termination and no recurrence at 1 year.