Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Difference from Background: Limit of Detection01:05

Difference from Background: Limit of Detection

The limit of detection (LOD) is the smallest amount of analyte that can be distinguished from the background noise. The LOD value corresponds to the concentration at which the analyte signal is three times larger than the standard deviation of the blank signal. Below this value, the analyte signal cannot be differentiated from the background noise. It is calculated by dividing the calibration slope by 3 times the standard deviation of the blank signals.
The LOD indicates the presence or absence...
Distance Corrections01:15

Distance Corrections

To achieve precise distance measurements, especially in surveying and construction, certain corrections must be applied to account for potential sources of error like the standardization errors, temperature variations, and slope adjustments.Standardization error emerges when measurement equipment undergoes changes, such as wear, repairs, or weather impacts. To address this, surveyors compare the equipment’s readings to a standard. This process identifies any deviation that might lead to...

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

A High-Phosphogypsum Multi-Solid-Waste Cementitious Binder for Backfill: Cross-Scale Insight into Pore Structure and Strength Development.

Materials (Basel, Switzerland)·2026
Same author

Thioredoxin attenuates ischemia-reperfusion-induced pressure ulcer formation by enhancing HIF-1α/BNIP3-dependent mitophagy and suppressing MAPK/NF-κB signaling.

Archives of biochemistry and biophysics·2026
Same author

Experimental Study on Macro and Meso Characteristics of Steel-Slag-Based Cemented Backfill Due to Microbial Mineralization Action.

Materials (Basel, Switzerland)·2024
Same author

Experimental study on influencing mechanism of the multiple effect of steel slag powder for coarse tailings cemented backfill.

Environmental science and pollution research international·2024
Same author

Engineering Characteristics and Microscopic Mechanism of Soil-Cement-Bentonite (SCB) Cut-Off Wall Backfills with a Fixed Fluidity.

Materials (Basel, Switzerland)·2023
Same author

Study of the Macro and Micro Characteristics of and Their Relationships in Cemented Backfill Based on SEM.

Materials (Basel, Switzerland)·2023

Related Experiment Video

Updated: Jul 16, 2026

Gain-compensation Methodology for a Sinusoidal Scan of a Galvanometer Mirror in Proportional-Integral-Differential Control Using Pre-emphasis Techniques
09:01

Gain-compensation Methodology for a Sinusoidal Scan of a Galvanometer Mirror in Proportional-Integral-Differential Control Using Pre-emphasis Techniques

Published on: April 4, 2017

Bias-correction subspace projection method for background noise suppression in OPM-MEG systems.

Fudan Zhao1, Haifeng Zhang2, Fengwen Zhao3

  • 1School of Electronic Information Engineering, Beihang University, Beijing, 100191, China; Institute of Large-Scale Scientific Facility and Centre for Zero Magnetic Field Science, Beihang University, Beijing, 100083, China.

Neuroimage
|July 14, 2026
PubMed
Summary

A new bias-correction subspace projection (BCSP) method improves noise suppression for wearable Magnetoencephalography (MEG) using optically pumped magnetometers (OPMs). This technique enhances signal quality for clearer brain imaging in neuroscience and clinical applications.

Keywords:
Background noise suppressionOPM-MEGSensor noise couplingSpatial filtering

More Related Videos

Post-Movie Subliminal Measurement (PMSM), for Investigating Implicit Social Bias
09:03

Post-Movie Subliminal Measurement (PMSM), for Investigating Implicit Social Bias

Published on: February 29, 2020

Related Experiment Videos

Last Updated: Jul 16, 2026

Gain-compensation Methodology for a Sinusoidal Scan of a Galvanometer Mirror in Proportional-Integral-Differential Control Using Pre-emphasis Techniques
09:01

Gain-compensation Methodology for a Sinusoidal Scan of a Galvanometer Mirror in Proportional-Integral-Differential Control Using Pre-emphasis Techniques

Published on: April 4, 2017

Post-Movie Subliminal Measurement (PMSM), for Investigating Implicit Social Bias
09:03

Post-Movie Subliminal Measurement (PMSM), for Investigating Implicit Social Bias

Published on: February 29, 2020

Area of Science:

  • Neuroimaging
  • Biophysics
  • Signal Processing

Background:

  • Optically pumped magnetometers (OPMs) enable wearable Magnetoencephalography (MEG) with flexible sensor placement.
  • Wearable OPM-MEG requires advanced environmental noise suppression due to sensor proximity to neural sources.
  • Conventional signal space projection (SSP) for noise reduction can be biased by sensor noise and environmental interference.

Purpose of the Study:

  • To develop a novel method for accurate noise subspace estimation in OPM-MEG.
  • To address the bias issue in conventional SSP methods for improved noise removal.
  • To enhance the signal-to-noise ratio (SNR) and preserve neural signal integrity in OPM-MEG.

Main Methods:

  • Proposed a bias-correction subspace projection (BCSP) method incorporating a sensor noise and magnetic field coupling model.
  • Utilized least-squares optimization to estimate and correct for subspace estimation bias.
  • Implemented an eigenvector correction strategy using nonlinear soft thresholding for adaptive bias reduction.

Main Results:

  • BCSP demonstrated superior noise suppression compared to conventional SSP in simulations and experiments.
  • The method significantly improved the signal-to-noise ratio (SNR) in OPM-MEG recordings.
  • Auditory evoked field experiments showed preserved N100 component waveform and highly focal cortical activation maps.

Conclusions:

  • The BCSP method offers a robust approach to noise suppression in OPM-MEG.
  • This technique enhances the reliability and focality of neuroimaging data.
  • BCSP holds significant potential for advancing OPM-MEG applications in clinical medicine and neuroscience research.