Deep learning fusion of multi-channel imaging from polarization-sensitive optical coherence tomography
Yunlong Liu1, Chen Wang2, Paul Calle1
1School of Computer Science, University of Oklahoma, Norman, OK, USA.
None:
Multi-contrast polarization-sensitive optical coherence tomography (PS-OCT) provides complementary structural and polarization information that may improve epidural tissue classification. Here, we evaluated deep learning fusion of four PS-OCT channels, including intensity, phase retardation, degree of polarization uniformity (DOPU), and optic axis, using porcine (n = 6) and human (n = 5) spinal specimens. We benchmarked six multi-channel fusion strategies: Probability averaging, feature concatenation, trainable weighted output, shared-stage resnet, merged multi-channel input, and pooled data. Across subject-level nested cross-validation, multi-channel methods achieved modest but consistent accuracy improvements over the best single-channel baselines while reducing subject-to-subject variability. On porcine data, Probability Averaging increased mean validation accuracy by 3.46% (93.07% vs. 89.61% for the best single-channel baseline). On human data, fusion methods maintained the high single-channel baseline (approximately 97% to 98%) while modestly improving stability, with probability averaging achieving the highest mean validation accuracy (98.26%). In cross-testing, trainable weighted output achieved 92.32% versus 91.53% for the best porcine single-channel baseline, and probability averaging achieved 97.87% versus 97.75% for the best human single-channel baseline. On the human cohort, the gain in mean accuracy was small, but multi-channel fusion produced a statistically significant reduction in between-subject variance (Levene's p = 0.0108) and removed the need to know in advance which single channel would generalize best. Overall, multi-channel fusion improved classification performance and robustness, with probability averaging offering a favorable balance between accuracy and complexity because it requires no additional training beyond single-channel models.
Related Concept Videos
Imaging Biological Samples with Optical Microscopy
In optical microscopy, the specimen to be viewed is placed on a glass slide and clipped on the stage...
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
Deconvolution
Deconvolution involves several mathematical techniques to derive the impulse response. One common approach is polynomial division. In this method, the input and output sequences are treated as coefficients of...
Electron Microscope Tomography and Single-particle Reconstruction
Electron Tomography
Electron tomography can be performed either in TEM or STEM (scanning transmission...
Imaging Studies III: Computed Tomography