Feasibility of early detection of left ventricular diastolic dysfunction in hypertensive patients using

Kun Peng1, Jiang Zhao1, Zijian Wang1

  • 1From the Department of Radiology, Shanghai Tenth People's Hospital, School of Medicine, Tongji University, 301 Middle Yanchang Road, Shanghai 200072, China.

Insights

Four-dimensional flow cardiac magnetic resonance (4D flow CMR) can detect early left ventricle diastolic dysfunction (LVDD) in hypertension (HTN). The kinetic energy (KE) E/A ratio shows diagnostic accuracy comparable to traditional methods, even without left ventricular hypertrophy (LVH).

Area of Science:

  • Cardiology
  • Medical Imaging
  • Biophysics

Background:

  • Hypertension (HTN) can lead to early left ventricle diastolic dysfunction (LVDD).
  • Left ventricular hypertrophy (LVH) is a common complication of HTN.
  • Detecting early LVDD is crucial for managing HTN and preventing cardiovascular events.

Purpose of the Study:

  • To evaluate the efficacy of four-dimensional flow cardiac magnetic resonance (4D flow CMR) in detecting early LVDD in patients with HTN.
  • To assess if 4D flow CMR can identify LVDD irrespective of the presence or absence of LVH.
  • To compare the diagnostic performance of 4D flow CMR-derived kinetic energy (KE) parameters with conventional echocardiographic assessments.

Main Methods:

  • Retrospective analysis of 66 HTN patients and 30 healthy controls.
  • Classification of HTN patients into LVH/non-LVH and LVDD/non-LVDD subgroups based on echocardiography.
  • Calculation and indexing of 4D flow CMR-derived LV KE parameters (KEiEDV, KE E/A ratio, in-plane KE, TD).
  • Comparison of KE parameters across groups and ROC curve analysis for LVDD detection.

Main Results:

  • HTN patients exhibited significantly altered KE patterns compared to controls.
  • The KE E/A ratio derived from 4D flow CMR showed high diagnostic accuracy (AUC 0.801-0.805) for LVDD detection in HTN patients, including those without LVH.
  • This accuracy was comparable to the echocardiographic parameter E/e' (AUC 0.810).

Conclusions:

  • 4D flow CMR-derived KE E/A ratio is a valuable tool for detecting early LVDD in HTN patients.
  • This method is effective even in the absence of LVH.
  • 4D flow CMR offers a promising non-invasive approach for assessing diastolic function in hypertensive individuals.