Impact of calibration approach on image quality and volumetric bone mineral density in low-dose chest computed
Bryn E Matheson1,2,3, Matthias Walle1,2,3, Steven K Boyd1,2,3
1McCaig Institute for Bone and Joint Health, Cumming School of Medicine, University of Calgary, Calgary, AB, Canada.
Abstract:
Opportunistic assessment of volumetric bone mineral density (vBMD) from computed tomography (CT) scans offers a strategy to identify individuals at risk of osteoporosis. However, accurate CT-based vBMD quantification depends on appropriate density calibration, and direct comparisons of synchronous, asynchronous, and tissue-based internal calibration in low-dose chest imaging are limited. This study had two objectives: (1) to assess the impact of calibration methods on image quality in low-dose chest CT, particularly whether the inclusion of a calibration phantom compromises image quality, and (2) to examine whether these variations influence agreement in vBMD measurements across calibration techniques. 51 participants underwent chest CT; 23 with a calibration phantom (synchronous) and 28 without (asynchronous). Trabecular vBMD was quantified at the fourth and eighth thoracic vertebrae (T4 and T8, respectively) and the first lumbar vertebra (L1). Image quality was assessed using stochastic noise and signal-to-noise ratio (SNR) in calibration phantom rods and tissue-based reference regions. Agreement in vBMD measurements was evaluated using Pearson's correlation coefficients, Bland-Altman analyses, and absolute deviations relative to internal calibration. Internal calibration tissues demonstrated stable image quality across synchronous and asynchronous acquisitions, whereas synchronously scanned calibration phantoms exhibited increased noise and reduced SNR. In vBMD measurements, asynchronous calibration demonstrated smaller deviations (19.15 ± 11.59 mg cm-3vs. 10.19 ± 9.69 mg cm-3) than synchronous across vertebral levels. These findings show that calibration strategy affects both image quality and vBMD agreement in low-dose chest CT. Asynchronous and tissue-based internal methods provided more consistent estimates than synchronous calibration, supporting their use for opportunistic osteoporosis assessment.
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
Imaging Studies for Cardiovascular System V: CT