Clinical applications with expired EBT-XD radiochromic film in radiotherapy
O A García-Garduño1, Y Ávila-Muñoz2, I Gamboa-deBuen3
1Laboratorio de Física Médica, Instituto Nacional de Neurología y Neurocirugía, México City, 14269, Mexico. oagarciag@innn.edu.mx.
Abstract:
Radiochromic films are widely used in radiotherapy dosimetry for their high spatial resolution and near-water-equivalence. Nonetheless, these films are frequently purchased in bulk, leading clinical departments to accumulate stock beyond the manufacturer's expiration date. Assessing the dosimetric performance of expired films may confer economic and environmental advantages. This work evaluated whether expired EBT-XD radiochromic films remain suitable for specific radiotherapy dosimetry applications. Two expired batches were compared with a non-expired batch. Dose-response curves were generated using a 6 MV photon beam from a clinical linear accelerator. The films were tested for small-field output factor measurements and patient-specific quality assurance (PSQA) in volumetric-modulated arc therapy (VMAT) and stereotactic radiosurgery (SRS), employing gamma-index analysis. Results indicated that expired films exhibit reduced sensitivity relative to unexpired films, particularly at lower dose levels. However, acceptable dosimetric agreement with unexpired films was observed for small-field output factors and high-dose SRS PSQA cases, provided appropriate recalibration was applied. More pronounced discrepancies emerged in low-dose VMAT PSQA measurements, where diminished film sensitivity may have influenced the film's response. These findings suggest that expired EBT-XD radiochromic films may still provide useful dosimetric information as relative dosimeters for selected radiotherapy measurements, especially when measurements fall within the film's recommended dose range, and films are properly stored and recalibrated.
More Related Videos
06:20Irradiator Commissioning and Dosimetry for Assessment of LQ α and β Parameters, Radiation Dosing Schema, and in vivo Dose Deposition
Published on: March 11, 2021
10:16Autoradiography as a Simple and Powerful Method for Visualization and Characterization of Pharmacological Targets
Published on: March 12, 2019
Related Concept Videos
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
X-ray Imaging
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...
Radiological Investigation I: X-ray and CT