Related Experiment Video
Updated: Aug 5, 2026

Ion-Exchange Membranes for the Fabrication of Reverse Electrodialysis Device
Published on: July 20, 2021
Thermodynamic Evaluation of a Triple-Pass Reverse Osmosis Seawater Desalination Plant: Energy and Exergy Perspectives
Abdulrahman S Almutairi1, Hani Abulkhair2,3, Saad F Almokmesh1
1Department of Mechanical Power and Refrigeration Technology, College of Technological Studies, Public Authority for Applied Education and Training, Shuwaikh, P.O. Box 42325, Kuwait City 70654, Kuwait.
Abstract:
Energy and exergy analyses were conducted on a triple-pass seawater reverse osmosis desalination system to evaluate thermodynamic performance and identify primary sources of irreversibility. A comprehensive simulation model, developed in IPSEpro (Version 7.0) and validated against manufacturer data, demonstrated strong agreement with the reported values. Exergetic efficiency of the reverse osmosis (RO) units increased across the passes, from 57% in the first pass to 80% and 78% in the second and third passes, respectively, while exergy destruction decreased correspondingly from approximately 375 kW in the first pass to 120 kW and 130 kW in the second and third passes. The pumping system, particularly the main high-pressure pump, was responsible for 49% of total exergy destruction, followed by the first RO unit at 23%. The impacts of feed water temperature, high-pressure pump pressure, and water recovery ratio (RC) on exergetic efficiency, specific energy consumption, and permeate flow rate were systematically assessed. Increasing the feed water temperature from 15 °C to 33 °C enhanced exergetic efficiency from 27.8% to 29.9% and reduced total exergy destruction from 1622 to 1582 kW, supporting the integration of hybrid RO-thermal desalination systems. The first-pass recovery ratio emerged as the most influential operational parameter overall, with exergetic efficiency rising from 25.1% to 33.7% as RC1 increased from 0.35 to 0.60. Analysis of the overall recovery ratio identified RC = 0.39 as a practical operating target that balances specific energy consumption of 4.05 kWh/m3 and exergy destruction of 1700 kW, offering the most favourable compromise between energy efficiency and thermodynamic performance. The results presented here provide practical guidance and recommendations for the optimization of the performance of large-scale multi-pass reverse osmosis seawater desalination plants.
Related Concept Videos
Osmosis and Osmotic Pressure of Solutions
Limits of the First Law of Thermodynamics
The Carnot Cycle
What could be the theoretical limit to the efficiency of a heat engine? The...
Thermodynamic Potentials
Conservation of Energy in Control Volume
For steady flow systems, the time derivative of the stored energy becomes zero since there is no energy accumulation within the control volume. This simplifies the energy equation to:
Heat Engines
Whenever we consider heat engines (and associated devices such as refrigerators and heat pumps), we do not use the standard sign convention for heat and work. For convenience, we assume that the symbols Qh, Qc, and W represent only the amounts of heat transferred...

