Related Experiment Video
Updated: Aug 5, 2026

Establishment of a Simple and Effective Rat Model for Intraoperative Parathyroid Gland Imaging
Published on: August 17, 2022
Diagnostic Contribution of SPECT/CT to Dual-Phase 99mTc-MIBI Parathyroid Scintigraphy for Preoperative Localization
Vuslat Mumcu Çimen1, Ebuzer Kalender2
1Department of Nuclear Medicine, Gaziantep City Hospital, 27470 Gaziantep, Turkey.
None:
Background: Accurate preoperative localization of hyperfunctioning parathyroid glands is essential for minimally invasive surgery in primary hyperparathyroidism (PHPT). Although dual-phase 99mTc-MIBI planar scintigraphy is widely used, its diagnostic performance may be limited in small or ectopic lesions. Hybrid SPECT/CT imaging combines functional and anatomical information and may improve localization accuracy. The aim of this study is to evaluate the diagnostic contribution of SPECT/CT to dual-phase 99mTc-MIBI planar scintigraphy for preoperative localization in patients with PHPT. Methods: This retrospective study included 128 patients with biochemically confirmed PHPT who underwent dual-phase 99mTc-MIBI planar scintigraphy followed by delayed-phase SPECT/CT imaging before parathyroidectomy between January 2020 and May 2024. Imaging findings were compared with postoperative histopathological results. Sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and accuracy were calculated. The effects of lesion size, biochemical parameters, and ultrasonographic findings on imaging performance were also evaluated. Results: Histopathology confirmed parathyroid lesions in 122 of 128 patients (95.3%). The sensitivity, specificity, PPV, NPV, and accuracy of planar imaging were 57.4%, 66.7%, 97.2%, 7.1%, and 57.8%, respectively, whereas those of SPECT/CT were 92.6%, 66.7%, 98.3%, 30.8%, and 91.4%, respectively. SPECT/CT findings showed significant concordance with histopathology (p = 0.001), while planar imaging did not (p = 0.247). Among lesions smaller than 1 cm, sensitivities were 37.1% for planar imaging and 91.4% for SPECT/CT. SPECT/CT also provided superior anatomical localization, particularly in ectopic lesions and in patients with concomitant thyroid pathology. Conclusions: SPECT/CT demonstrated substantially higher diagnostic performance than dual-phase planar scintigraphy for preoperative localization in PHPT. Its incremental value was particularly evident in subcentimeter lesions, ectopic parathyroid adenomas, and patients with coexisting thyroid disease.
Related Concept Videos
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...
Imaging Studies for Cardiovascular System V: CT
Imaging Studies III: Computed Tomography