Related Experiment Video
Updated: Aug 5, 2026

The Modular Design and Production of an Intelligent Robot Based on a Closed-Loop Control Strategy
Published on: October 14, 2017
Research on Live Working Robots for 10 KV Distribution Networks Adopting Four-Dimensional Safety Guarantee Framework
Xiaohui Xie1, Lining Sun1,2, Pan Luo1
1Robot and Microsystem Technology Research Center, Soochow University, Suzhou 215137, China.
Abstract:
Traditional manual 10 kV live-line maintenance is accompanied by high personal risks and incomplete safety protection, while overall operational efficiency is limited. This paper develops an intelligent live-working robot based on a tracked insulated spider aerial vehicle. The system is equipped with vertical lifting modules and a pair of 6-DOF insulated manipulators to form a 13-DOF integrated motion platform. Binocular cameras, LiDAR, real-time insulation monitors, and electromagnetic interference detectors are integrated as multi-modal sensing hardware to achieve high-precision positioning of overhead lines and pole fittings. A master-slave collaborative control strategy combined with mixed reality (MR) and visual auxiliary force feedback is proposed to coordinate the tracked chassis, lifting structure, and dual manipulators. A four-dimensional full-cycle safety guarantee framework is further constructed, covering insulation protection, anti-interference communication, human-machine risk avoidance, and full-task supervision to support real-time early warning and motion interlock. Field tests on actual 10 kV distribution lines verify stable positioning performance under controlled test conditions, and no safety accidents occurred in all trials. The designed robotic system provides an optional technical scheme for intelligent unmanned live-line maintenance of distribution networks.
Related Concept Videos
Zones of Protection
Protective zones are defined by closed dashed lines, containing one or more components. A key characteristic of these zones is the strategic placement of...
Distribution Reliability and Automation
Reclosers and Fuses
A comprehensive protection scheme for radial distribution...
Transformers in Distribution System
Distribution substation transformers come in various ratings and typically use mineral oil for insulation and cooling. To prevent moisture and air from entering the oil, some transformers use an inert gas like nitrogen to fill the...
Radial System Protection
In a radial system with a fault downstream of the third breaker, ideally, only the third breaker will open, isolating the fault and interrupting the load connected beyond it. The second breaker has a longer delay setting,...