Related Experiment Video
Updated: Aug 5, 2026

Measurement of Particle Size Distribution in Turbid Solutions by Dynamic Light Scattering Microscopy
Published on: January 9, 2017
Spatially and angularly resolved spectroscopy for in situ estimation of particle size and concentration in particle
Carla Ferreira1,2, Javier Cardona1,2,3, Okpeafoh Agimelen1,2
1CMAC, University of Strathclyde, Glasgow, G1 1RD, UK.
Abstract:
Accurate in-line monitoring of particle size and solid concentration in turbid, multiphase systems remains a significant challenge in pharmaceutical manufacturing. Most particle measurement techniques are developed for off-line analysis, while recent in-line methods mainly rely on imaging and chord length distribution (CLD) measurement. Complementing these approaches, the spatially and angularly resolved diffuse reflectance measurement (SAR-DRM) system serves as a process analytical technology analyzer, capturing detailed, configuration-dependent spectral responses of particle suspensions. This study systematically evaluates SAR-DRM's effectiveness in analyzing a wide range of particle diameters (≤90-800 µm) and concentrations (1-10 wt%) for polystyrene suspensions. The visible-NIR and NIR measurements from its multiple spatial-angular fiber configurations are further analyzed to assess their potential in complementing other in-line techniques, improving interpretability and analytical performance. The results show that combining specific SAR-DRM configurations through data augmentation markedly enhances model performance compared to individual configurations or co-adding methods, reducing error by over 50% in some cases. Moreover, data fusion of SAR-DRM with CLD measurements yields the most accurate models, particularly for mid-sized particles, decreasing the prediction error to 10-12 µm. The study highlights SAR-DRM as a promising process analytical technology analyzer for particulate process monitoring, paving the way for advanced hybrid modelling in pharmaceutical and chemical manufacturing. It also underscores the complementary sensing capabilities of SAR-DRM and CLD measurements, providing a robust multisensory platform for real-time, quantitative analysis in complex, high-turbidity systems.
Related Concept Videos
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used.
Size-Exclusion Chromatography
Silica particles offer advantages such as rigidity,...

