Related Experiment Video
Updated: Aug 5, 2026

07:51
Reliability of A Vibration-Based Elastography Protocol For Assessing Achilles Tendon Stiffness Across Multiple Joint Angles In Elite Athletes
Published on: June 16, 2026
Do Ober Tests Reflect Iliotibial Band Stiffness? A Preliminary Shear Wave Elastography Study
Akihiro Asayama1,2,3, Masahide Yagi1,2, Hiroshige Tateuchi1
1Human Health Sciences, Graduate School of Medicine, Kyoto University, Kyoto, Japan.
Journal of Sport Rehabilitation
|August 3, 2026
Summary
Traditional Ober tests may not accurately measure iliotibial band (ITB) stiffness in vivo. Modified Ober and hip extension tests show greater potential for assessing ITB stiffness.
Area of Science:
- Biomechanics
- Musculoskeletal imaging
- Clinical assessment
Background:
- Iliotibial band (ITB) stiffness is commonly assessed using Ober and modified Ober tests.
- The in vivo accuracy of these tests for evaluating ITB stiffness remains uncertain.
- Alternative clinical tests may offer better insights into ITB stiffness.
Purpose of the Study:
- To investigate the in vivo validity of traditional and alternative clinical tests for assessing iliotibial band (ITB) stiffness.
- To determine which clinical tests best correlate with objective measures of ITB stiffness.
Main Methods:
- Cross-sectional study involving 35 healthy males.
- Clinical tests included traditional Ober, modified Ober, and hip extension with tibial external rotation tests, with defined positive cutoff values.
- Shear wave elastography measured the stiffness of the ITB and surrounding muscles (rectus femoris, tensor fascia lata, gluteus medius, gluteus minimus).
- Multivariable logistic regression analyzed associations between clinical test findings and tissue stiffness.
Main Results:
- Higher ITB stiffness was significantly associated with positive findings in the modified Ober test with the hip in extension (OR=1.03, P=.04) and the hip extension test with tibial external rotation (OR=1.04, P=.03).
- The traditional Ober and modified Ober tests showed no significant association with ITB stiffness.
- Shear wave elastography provided objective in vivo stiffness measurements.
Conclusions:
- Traditional Ober-based tests appear to have limited utility for evaluating iliotibial band (ITB) stiffness in vivo.
- Modified testing positions, specifically the modified Ober test with hip extension and the hip extension test with tibial external rotation, may offer more reliable assessments of ITB stiffness.
- These findings suggest a need to reconsider standard clinical assessment protocols for ITB stiffness.
