Strain Sensing Based on Multiscale Composite Materials Reinforced with Graphene Nanoplatelets
Published on: November 7, 2016
Double-Layer Graphene Mesh/PEDOT:PSS Conductive-Network-Reinforced PDMS Nanocomposites for Temperature-Insensitive
Lei Wang1, Zhiqiang Bai1, Ruijie Han1,2
1Henan Key Laboratory of Advanced Cable Materials and Intelligent Manufacturing, Henan Institute of Technology, Xinxiang 453003, China.
Abstract:
Conductive polymer composite (CPC)-based wearable electronics and flexible strain sensors work in different environments, which require CPCs to show stable electrical performance at a wide range of temperatures. However, the resistance of most CPCs is generally temperature-dependent. In this work, a double-layer conductive framework was fabricated by coating highly conductive poly(3,4-ethylenedioxythiophene) polystyrene sulfonate (PEDOT:PSS) on a graphene mesh. The resulting composite, PEDOT:PSS/GM/PDMS-0.75, exhibited outstanding conductivity (8.1 S/cm), a high gauge factor (~42), excellent reliability (1000 cycles) and stable sensing performance within -30~140 °C. This work highlights the importance of PEDOT:PSS in improving the conductive stability of graphene-based strain sensors at different temperatures. Moreover, applications of sensing for human joint movement in different environments open new opportunities for temperature-insensitive CPCs.