A Novel Digital Platform for a Monitored Home-based Cardiac Rehabilitation Program
Published on: April 19, 2019
Continuous Cuffless Blood Pressure Estimation Using a Multimodal Conv1D-LSTM Architecture and the SOUNDI® Wearable
Dario Bovio1, Alice Turrini2, Alice Prandoni1
1Biocubica Srl, 20154 Milan, Italy.
Abstract:
Arterial blood pressure (BP) is a crucial physiological parameter reflecting cardiovascular function and exhibiting dynamic oscillations in response to physiological, psychological, and environmental changes. Since conventional cuff-based measurements provide only intermittent "snapshot" readings, there is growing interest in reliable cuffless and noninvasive systems capable of capturing BP dynamics over time. This work proposes a continuous cuffless BP estimation system based on SOUNDI®, a proprietary wearable device for multimodal physiological and environmental monitoring developed by Biocubica srl. An end-to-end neural network architecture combining convolutional and long short-term memory (LSTM) layers was designed to automatically extract features from pre-processed signals and directly predict systolic and diastolic BP (SBP and DBP). Data were collected from 20 healthy subjects (7 females, 13 males) using a tailored acquisition protocol with reference targets acquired through the validated GIMA® ABPM50 device. Model performance was evaluated using both a Leave-One-Subject-Out (LOSO) cross-validation framework to assess subject-independent generalizability and a conventional 80/20 segment-level split reflecting a personalized monitoring setup. Under the subject-independent LOSO cross-validation, the model achieved a best-subject MAE of 4.93 mmHg for SBP and 3.76 mmHg for DBP, demonstrating the feasibility of generalizing across unseen individuals despite inter-subject physiological variability. Under the conventional 80/20 split, the framework achieved an MAE of 2.98 mmHg for SBP and 2.68 mmHg for DBP, with RMSE values of 4.16 mmHg and 3.72 mmHg, respectively, and Pearson correlation coefficients of R = 0.95 for SBP and R = 0.94 for DBP. These results establish a promising feasibility proof-of-concept for multimodal cuffless BP tracking under dynamic states and nocturnal conditions, highlighting both the strength of multi-sensor fusion and the value of lightweight calibration for real-world deployment on larger, clinical cohorts.
Related Concept Videos
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Measurement of Blood Pressure
Korotkoff Sounds
During blood pressure assessment, inflating the cuff 30 millimeters of mercury above the patient's systolic blood pressure...
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement