Related Experiment Video
Updated: Aug 28, 2026

Optimizing Minimally Invasive Spine Surgery: A Fully 3D CT O-Arm Navigated Workflow in MIS TLIF
Published on: October 17, 2025
VLM-Assisted Routing and HU-Traceable DICOM Adaptation for Lumbar CT HU Measurement: A Deployment-Oriented Pilot
Zhe-Yu Ye1, Jun-Mu Peng1, Tamotsu Kamishima1
1Faculty of Health Sciences, Hokkaido University, Sapporo 060-0812, Japan.
Abstract:
Automated lumbar computed tomography (CT) Hounsfield unit (HU) measurement can support opportunistic osteoporosis screening, but heterogeneous Digital Imaging and Communications in Medicine (DICOM) inputs often disrupt automated workflows before measurement. We evaluated a local Qwen2.5-VL-7B vision-language model (VLM)-assisted front end for suitability routing, input planning, and HU-traceable DICOM-derived field-of-view/orientation adaptation upstream of an unchanged single-slice lumbar CT HU workflow. The VLM was restricted to routing and planning. In a 20-case FUJIFILM pilot cohort, observed HU output availability was higher with the front-end-assisted route than with direct processing (12/20 versus 5/20), while paired automatic-success cases showed excellent agreement with post hoc manual ImageJ (version 1.54g) measurements (ICC(A,1) = 0.997; MAE = 4.64 HU). Public DICOM stress testing further demonstrated improved workflow robustness across heterogeneous datasets. These findings support the use of a deployment-oriented front-end strategy to improve the auditability and robustness of automated lumbar CT HU measurement while preserving an unchanged downstream measurement workflow.