Related Experiment Video
Updated: Aug 28, 2026

Dual-mode Imaging of Cutaneous Tissue Oxygenation and Vascular Function
Published on: December 8, 2010
Nostril-Anchored Geometric ROI Projection for Contactless Forehead Skin Temperature Estimation Using Low-Resolution
Riska Analia1,2, Anne Forster3, Sheng-Quan Xie1
1School of Electronic and Electrical Engineering, University of Leeds, Leeds LS2 9JT, UK.
Abstract:
(1) Background: Reliable forehead region-of-interest (ROI) localization remains challenging in low-resolution thermal imaging because limited spatial detail increases localization uncertainty. This study develops a lightweight nostril-anchored geometric ROI projection method for contactless forehead skin temperature estimation. (2) Methods: The forehead ROI was projected from the detected nostril bounding box using anthropometry-guided proportional geometry, followed by 95th-percentile (P95) spatial aggregation and exponential moving average (EMA) stabilization. Direct localization was evaluated against fixed-crop and MediaPipe Pose-based baselines using 120 annotated pilot frames across 0.5-1.5 m, followed by validation on 150 additional annotated frames from ten formal participants. A medical non-contact infrared forehead thermometer targeting the same central forehead region was used as a practical, rather than traceably calibrated, comparator. (3) Results: The proposed method outperformed the two localization baselines in the pilot evaluation. Formal-cohort validation achieved an overall IoU of 0.714, FIR of 0.870, and NCE of 0.091, with a 0.7% spatial-failure rate. Across 90 temperature measurements, the method achieved an MAE of 0.514 °C, RMSE of 0.614 °C, and mean bias of -0.187 °C, with 95% Bland-Altman limits of agreement from -1.340 °C to 0.966 °C. Real-time implementation achieved 24.12±1.43 FPS on a Jetson Orin Nano. (4) Conclusions: The proposed method provides a computationally efficient forehead ROI localization approach for low-resolution thermal imaging. Localization was strongest at 0.5 m and lower at farther distances; therefore, its scale adaptation should not be interpreted as distance-invariant performance. The temperature results represent agreement with the practical comparator rather than absolute clinical accuracy.
Related Concept Videos
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's forehead...
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Assessing Body Temperature - Tympanic membrane
Step 1: Begin by practicing good hand hygiene to prevent the transmission of microorganisms.
Step 2: Turn on the thermometer and wait until the ready sign appears on the screen to ensure accurate measurement.
Step 3: Slide the probe cover in place to prevent cross-contamination.
Step 4: Instruct the patient to tilt their head to the side for comfort and check for cerumen...

