Allergic contact dermatitis following usage of adhesive mesh dressing in knee replacement surgeries does not affect
Jonathan Kow1, Shawn Js Seah1, Cheryl Gatot1
1Department of Orthopedic Surgery, Singapore General Hospital, Singapore.
Abstract:
PurposeDermabond Prineo, a 2-octyl cyanoacrylate adhesive mesh dressing, is widely used in knee arthroplasty for rapid watertight closure. Allergic contact dermatitis (ACD) has been reported in approximately 5% of Western cohorts, with repeat exposure as a key risk factor. This study evaluated incidence, risk factors, and short-term outcomes in an Asian population.MethodsA single-centre retrospective cohort study included 290 consecutive patients undergoing primary total or unicompartmental knee arthroplasty (2022-2023) with 6-month follow-up. ACD was diagnosed clinically. Outcomes included ROM, KSS, KSF, OKS, and SF-36 scores. Logistic regression identified risk factors.ResultsACD occurred in 19 patients (6.6%) at a mean of 21 days. No cases progressed to prosthetic joint infection. Younger age (OR 0.90, p=0.003) and prior Dermabond exposure (adjusted OR 3.12, p=0.034) independently predicted ACD. Six-month outcomes were comparable between groups.ConclusionACD is uncommon and does not affect short-term outcomes, though younger and previously exposed patients are at higher risk.