Related Experiment Video
Updated: Sep 5, 2026

Expedited Radiation Biodosimetry by Automated Dicentric Chromosome Identification (ADCI) and Dose Estimation
Published on: September 4, 2017
Point-of-Care Radiation Biodosimetry via a Body-Heated Reverse Transcription-Recombinase Polymerase Amplification
Ashkan Khanishayan1, Jerome Lacombe1,2, Jasmine Pramila Devadhasan1
1Center for Applied NanoBioscience and Medicine, College of Medicine Phoenix, University of Arizona, 475 North Fifth Street, Phoenix, Arizona85004, United States.
Abstract:
Rapid biodosimetry at the point of care is critical for efficient triage and clinical management during mass-casualty radiological events. Here, we introduce a power-free biodosimetry platform integrating one-step reverse transcription recombinase polymerase amplification (RT-RPA) with vertical flow immunoassay (VFI) for the multiplex detection of two radiation-responsive transcripts (CDKN1A and DDB2) and housekeeping gene (MRPS5) from fingerstick blood. One-step RT-RPA showed optimal efficiency at 36 °C for 20 min, comparable to two-step RT-RPA and standard PCR. This temperature could be provided by the human body, where the axilla delivered a stable heat source (36.2 °C) with minimal interindividual variability across a range of environmental conditions (from 4 to 42 °C), supporting amplification comparable to thermocycler-based reactions. Amplified products were detected using a capillary-driven VFI platform. The assay demonstrated strong specificity, uniform signal distribution, and reproducibility with intra- and interassay coefficient of variation below 10% and 15%, respectively, across all three transcripts. When applied to ex vivo X-ray irradiated blood samples (1 and 2 Gy), a dose-dependent increase in CDKN1A and DDB2 signals was observed. Receiver operating characteristic analysis demonstrated that discrimination between sham- and 1 Gy-irradiated was not significant, whereas the assay distinguished sham- from 2 Gy-irradiated with area under the curve values of 0.82 (95% CI = [0.66-0.98]; p = 0.0052) and 0.89 (95% CI = [0.76-1.00]; p = 0.0006) for CDKN1A and DDB2, yielding sensitivity/specificity of 84.62%/69.23% and 92.31%/84.62%, respectively. These findings supported the feasibility of the body-heat one-step RT-RPA VFI as a rapid, equipment-free, field-deployable triage tool for large-scale radiation biodosimetry.
More Related Videos
06:00Portable Paper-Based Immunoassay Combined with Smartphone Application for Colorimetric and Quantitative Detection of Dengue NS1 Antigen
Published on: January 26, 2024
10:35A Blood-based Test for the Detection of ROS1 and RET Fusion Transcripts from Circulating Ribonucleic Acid Using Digital Polymerase Chain Reaction
Published on: April 5, 2018