Preoxygenation Techniques for Tracheal Intubation in Critically Ill Adults Utilizing Oxygen Mask and Noninvasive Ventilation
Published on: December 5, 2025
Personalized Oxygen Saturation Targets Compared to the Oxygen Saturation Experienced in Care Among Mechanically
Kevin P Seitz1, Alexandra B Spicer2, Kevin G Buell3
1Vanderbilt University Medical Center, Department of Medicine, Division of Allergy, Pulmonary and Critical Care Medicine, Nashville, TN.
Rationale:
For critically ill adults receiving invasive mechanical ventilation, randomized trials have found no significant average treatment effect of a higher (96-100%) versus lower (88-92%) peripheral oxygen saturation (SpO2) target. The effect of SpO2 targets on outcomes, however, may differ for patients with different characteristics. Machine learning methods have been used recently to derive and validate a statistical model capable of predicting which SpO2 target will result in lower mortality for an individual patient, as a personalized SpO2 target. Personalized targets can only improve patient outcomes, however, if the SpO2 target predicted to be best for them differs from the SpO2 values they are already experiencing in care. Whether the SpO2 values experienced in clinical care differ for patients predicted to benefit from a higher vs a lower SpO2 target is unknown.
Methods:
Among consecutive patients receiving invasive mechanical ventilation in an intensive care unit, we used the previously validated machine learning model to calculate a personalized SpO2 target (predicted to benefit from a higher SpO2 target (96-100%) vs predicted to benefit from a lower SpO2 target (88-92%)) from baseline characteristics for each patient. We compared the personalized SpO2 target as the primary exposure to the observed SpO2 values experienced in clinical care as the primary outcome using a proportional odds model accounting for within-subject correlation. FiO2 values received in clinical care were analyzed as the secondary outcome.
Measurements And Main Results:
Among 615 patients (median age, 58 years; 41% female), 325 (53%) were predicted by the machine learning model to benefit from a higher SpO2 target and 290 (47%) were predicted to benefit from a lower SpO2 target. Patients predicted to benefit from higher and lower targets experienced similar SpO2 values (mean 96.2% vs 95.6%; median 97% vs 96%; adjusted median difference 0.3%; 95%CI: -0.1% to 0.6%; P = 0.18) and FiO2 values (mean 0.45 vs 0.47; median 0.40 vs 0.40; adjusted median difference -0.02; 95%CI: -0.07 to 0.03; P = 0.38) in clinical care. In subgroups of interest, differences in the SpO2 or FiO2 values between groups were found only among patients with shock.
Conclusions:
In current clinical care, patients do not experience SpO2 values consistent with those predicted to result in the best outcomes for them, based on a machine learning model derived and validated in data from prior clinical trials. This lack of difference in care suggests that using evidence-based personalized oxygen saturation targets to guide oxygen administration in clinical care has the potential to improve outcomes.
More Related Videos
14:28Non-Invasive Monitoring of Microvascular Oxygenation and Reactive Hyperemia using Hybrid, Near-Infrared Diffuse Optical Spectroscopy for Critical Care
Published on: May 10, 2024
07:52Expired CO2 Measurement in Intubated or Spontaneously Breathing Patients from the Emergency Department
Published on: January 29, 2011
Related Concept Videos
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is important.
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Respiratory Assessment: Purpose and Indications
Objectives and Importance:
The primary goal of respiratory assessment is to evaluate patients at early risk of clinical deterioration. Since respiratory distress often precedes other signs of declining health, breathing patterns and sounds become a...
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...