Continuous sampling/transfer strategy to overcome sampling-volume mismatch in heart-cutting two-dimensional liquid
Xiao Gu1, Qiqian Zhao2, Xiaoxue Xiong2
1Zhejiang Institute for Food and Drug Control, Zhejiang Key Laboratory of Biopharmaceutical Contact Materials, Hangzhou, China.
Abstract:
Heart-cutting two-dimensional liquid chromatography (2D-LC) is widely used for pharmaceutical impurity profiling but suffers from sampling‑volume mismatch between the fixed loop volume and the elution volume of the target peak. Under‑sampling with small loops causes loss of sensitivity, whereas over‑sampling using an oversized loop leads to severe band broadening. Here we introduce a Continuous Sampling/Transfer (CST) strategy that overcomes this mismatch using remarkably simple hardware: only two identical loops and a standard 2‑position/4‑port duo valve. This system enables quantitative transfer of entire peaks irrespective of width by slicing the target peak into discrete fractions and transferring each immediately to the second dimension. Transfer efficiency exceeds 98%, with excellent linearity (r > 0.9999) and repeatability (RSD = 0.2%, n = 6). The utility of CST was demonstrated by impurity profiling of ertapenem for injection using size‑exclusion - reversed‑phase 2D‑LC. The CST interface precisely transferred eight peaks of varying widths from the first dimension and resolved 15 impurities in the second dimension, including two co‑eluting pairs undetectable by one‑dimensional RP method. High‑resolution mass spectrometry identified five previously unreported impurities. The CST strategy offers a hardware‑simple, robust solution to sampling‑volume mismatch, enabling in‑depth impurity profiling and separation performance assessment.
More Related Videos
11:17Multiplex Therapeutic Drug Monitoring by Isotope-dilution HPLC-MS/MS of Antibiotics in Critical Illnesses
Published on: August 30, 2018
10:37Deep Proteome Profiling by Isobaric Labeling, Extensive Liquid Chromatography, Mass Spectrometry, and Software-assisted Quantification
Published on: November 15, 2017
Related Concept Videos
High-Performance Liquid Chromatography: Elution Process
Sampling Methods: Sample Types
Solid samples include a variety of substances, such as sediments from water bodies, soil, metals, and biological tissues. Two standard methods for extracting sediments from water bodies are grab sampling and piston coring. Grab sampling involves using a device to collect a discrete sediment sample from the bottom of a water body with minimal disturbance. Grab samples do not always represent the entire area due to...