Related Experiment Video
Updated: Sep 18, 2026

Preparing an Isotopically Pure 229Th Ion Beam for Studies of 229mTh
Published on: May 3, 2019
Continuous-wave laser absorption spectroscopy of the thorium-229 nucleus
I Morawetz1, T Riebner1,2, L Toscani De Col1
1Vienna Center for Quantum Science and Technology, Atominstitut, TU Wien, Vienna, Austria.
Abstract:
The low-energy nuclear transition in thorium-229 (Th-229) has been excited in thorium-doped crystals with laser light1-3, opening the path towards a highly stable and robust solid-state optical nuclear clock4. The required laser radiation at 148-nm wavelength has so far been produced using pulsed laser systems, in which only a small fraction of the incident photons has been resonant with the narrow nuclear transition. Here we show that the nucleus can be excited with a continuous-wave (CW), narrow-bandwidth, solid-state laser source5 at sub-nanowatt power and that the nuclear resonance signal can be detected in absorption rather than fluorescence. This eliminates the slow nuclear fluorescence decay from the detection process, allowing for clock operation with fast signal acquisition. We characterize two different thorium centres in a calcium fluoride (CaF2) crystal and measure the isomeric shift between them. One of the centres shows a very small static electric crystal field gradient <0.1 V Å-2 compared with gradients in the range of 100 V Å-2 observed previously3,6. This indicates a centre with high symmetry of the ions surrounding the thorium nucleus, promising nuclear resonance lines that are nearly independent of the lattice spacing.
More Related Videos
Related Concept Videos
Atomic Spectroscopy: Absorption, Emission, and Fluorescence
Atomic Absorption Spectroscopy: Instrumentation
The atomizer used in AAS can be either a flame atomizer or an...
Atomic Absorption Spectroscopy: Radiation and Light Sources
Two common narrow-range 'line' sources used in AAS are hollow-cathode lamps (HCLs) and...
Atomic Absorption Spectroscopy: Interference
Spectral interference occurs when signals from other elements or molecules overlap with the analyte signal, falsely elevating or masking the analyte's absorbance. This interference can be corrected using Zeeman,...
Atomic Absorption Spectroscopy: Overview
When irradiated by EMR of a particular wavelength, these...
Atomic Absorption Spectroscopy: Lab
Solutions containing organic solvents, such as low-molecular-mass alcohols, esters, or ketones, enhance absorbances by increasing nebulizer...