Related Experiment Video
Updated: Sep 23, 2026

Single-Molecule Surface-Enhanced Raman Scattering Measurements Enabled by Plasmonic DNA Origami Nanoantennas
Published on: July 21, 2023
Single-molecule DNA hybridisation studied by using a modified DNA sequencer: a comparison with surface plasmon
Jens Sobek1, Hubert Rehrauer1, Stefan Schauer1
1Functional Genomics Center Zurich, Eidgenössische Technische Hochschule (ETH) Zurich and University of Zurich, Winterthurerstrasse 190, 8057 Zurich, Switzerland.
Abstract:
Current methods for the determination of molecular interactions are widely used in the analytical sciences. To identify new methods, we investigated as a model system the hybridisation of a short 7 nt oligonucleotide labelled with, structurally, very similar cyanine dyes CY3 and DY-547, respectively, to a 34 nt oligonucleotide probe immobilised in a zero-mode waveguide (ZMW) nanostructure. Using a modified commercial off-the-shelf DNA sequencer, we established the principles to measure biomolecular interactions at the single-molecule level. Kinetic data were obtained from trains of fluorescence pulses, allowing the calculation of association and dissociation rate constants (kon,koff). For the 7mer labelled with the positively charged CY3 dye,konandkoffare ~3 larger and ~2 times smaller, respectively, compared with the oligonucleotide labelled with negatively charged DY-547 dye.The effect of neighbouring molecules lacking the 7nt binding sequence on single-molecule rate constants is small. The association rate constants is reduced by only 20-35%. Hybrid dissociation is not affected, since as a consequence of the experimental design, rebinding cannot take place.Results of single-molecule experiments were compared with data obtained from surface plasmon resonance (SPR) performed under comparable conditions. A good correlation for the association rate constants within a factor of 1.5 was found. Dissociation rate constants are smaller by a factor of 2-3 which we interpreted as a result of rebinding to neighbouring probes.Results of SPR measurements tend to systematically underestimate dissociation rate constants. The amount of this deviation depends on the association rate constant and the surface probe density. As a consequence, it is recommended to work at low probe densities to keep this effect small.
Related Concept Videos
Sanger Sequencing
Next-generation Sequencing
Next-Generation Sequencing Methods
Although all next-generation methods use different technologies, they all share a set of standard features.
Labeling DNA Probes
Radioisotopes, fluorophores, or small molecule binding partners like biotin or digoxigenin, are the most widely used reporter tags for labeling DNA probes. These labels can be attached to the probe DNA molecule via...
Southern Blot
Denatured DNA fragments must be transferred onto a carrier membrane from the gel to make it accessible to a probe - a small ssDNA fragment complementary to the target DNA...
Maxam-Gilbert Sequencing
Challenges of the Maxam-Gilbert Method
The...