[Reproducibility of pulse oximetry in the fingers of the hands]
Luis Efrén Santos-Martínez1, Nancy Imelda Colín-Chávez1, Jessica Paola Durán-Vidauri1
1Instituto Mexicano del Seguro Social, Centro Médico Nacional Siglo XXI, Hospital de Cardiología, Departamento de Hipertensión Pulmonar y Corazón Derecho. Ciudad de México, México.
Background:
Partial oxygen saturation from pulse oximetry is most often obtained from the fingers of the hands; however, it is not known whether any of the fingers are ideal for estimating partial oxygen saturation.
Objective:
To describe the partial oxygen saturation behaviour obtained from the fingers of both hands.
Material And Methods:
Using a cross-sectional analytical design, the partial oxygen saturation was consecutively estimated in the fingers of both hands. Demographic data were obtained from healthy subjects, and they were analyzed using repeated-measures analysis of variance; reproducibility was calculated using the mean difference (limits of agreement) and its magnitude using the intraclass correlation coefficient or ICC (95% confidence interval [95% CI]); a p value < 0.05 was considered significant.
Results:
1000 determinations of partial oxygen saturation were studied from the fingers of both hands of 100 subjects (64% women) whose average age was 34 ± 10 years old and whose body mass index (BMI) was of 23.5 ± 5 kg/m2. Partial oxygen saturation was 90.3 ± 4% and reproducibility was almost perfect in all combinations; however, the right index finger versus right ring finger combination was the best: 90.3 ± 4.1% versus 90.5 ± 4% mean difference (limits of agreement) -0.2 (2.5, -2.8) between both and the ICC (95% CI) 0.942 (0.916, 0.961).
Conclusions:
Partial oxygen saturation is reproducible in all fingers, with no clinically relevant differences.
Related Concept Videos
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is important.
Assessment of radial pulse
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps:
Pulse
The pulse serves as a clinical indicator...
Special considerations while measuring pulse


