Related Experiment Video
Updated: Sep 24, 2026

23:33
The WATCHMAN Left Atrial Appendage Closure Device for Atrial Fibrillation
Published on: February 28, 2012
Percutaneous Left Atrial Appendage Closure Using a PFO Occluder After an Incomplete Surgical Ligation
Zach Rozenbaum1,2, Eric Gnall3
1Department of Cardiology, Tulane University, New Orleans, Louisiana, USA.
Abstract:
The case regards a 73-year-old male who was referred for consideration of percutaneous left atrial appendage closure. His left atrial appendage was ligated during prior mitral valve surgery, but was noted to be patent on a recent transesophageal echocardiography. An Amulet device was selected based on CT planning. This report describes a challenging appendage anatomy unsuitable for the commercial devices, managed successfully with an off-label device.