Comparison of Artificial Intelligence-Driven Echocardiographic Assessment of Diastolic Function With the ASE
Márton Tokodi1, Nobuyuki Kagiyama2, Ambarish Pandey3
1Heart and Vascular Center, Semmelweis University, Budapest, Hungary; Department of Experimental Cardiology and Surgical Techniques, Semmelweis University, Budapest, Hungary.
Background:
Contemporary guideline-based assessment of left ventricular diastolic function and filling pressure requires multiple echocardiographic parameters that may not be routinely acquired in real-world clinical practice.
Objectives:
The aim of the study was to compare the prognostic and diagnostic performance of a previously validated deep learning (DL) model for left ventricular diastolic function assessment with those of the 2016 ASE (American Society of Echocardiography)/EACVI (European Association of Cardiovascular Imaging) and 2025 ASE guidelines.
Methods:
The DL model and the guidelines were compared in the ARIC (Atherosclerosis Risk In Communities) cohort (n = 5,450) for prognostication and in 2 hemodynamic validation cohorts from the United States (n = 83) and Japan (n = 130) for diagnosing elevated left ventricular filling pressure. In all 3 cohorts, ≥1 guideline-recommended parameters were unavailable in a substantial proportion of patients.
Results:
In the ARIC cohort, the DL model achieved a higher C-index than both the 2016 ASE/EACVI and 2025 ASE guidelines (0.676 vs 0.638 and 0.602, respectively; both P < 0.001). In the United States cohort, the DL model achieved a higher area under the receiver operating characteristic curve (AUC) than the 2025 ASE guidelines (0.879 vs 0.822; P = 0.041) and a similar AUC to the 2016 ASE/EACVI guidelines (0.879 vs 0.812; P = 0.138). In the Japanese cohort, the DL model achieved a higher AUC than both guideline versions (0.816 vs 0.694 and 0.634, respectively; both P < 0.05).
Conclusions:
In settings where not all guideline-recommended parameters are available, the DL model may improve prognostic and diagnostic performance compared with both guideline versions. Nevertheless, these exploratory findings require further validation to confirm that the observed advantages persist when all guideline-recommended parameters are systematically acquired.
Related Concept Videos
Imaging Studies for Cardiovascular System I:Echocardiography
Indications: Echocardiography is utilized to diagnose heart failure, valve disorders, and myocardial infarction. It also assesses cardiac structures' size, shape, and motion, evaluates...
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for diagnosing...
Pre-Procedural Guidelines for Assessing Blood Pressure
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Assessment of blood pressure in brachial artery(two-step method)
Assessment of the Cardiovascular System IV: Auscultation
Normal Heart Sounds
S1 (First Heart Sound)-
S1 is made by the closure of the mitral and tricuspid valves (atrioventricular valves), marking the beginning of systole.
S2 (Second Heart Sound)-
S2 is made by the closure of the aortic and pulmonic valves (semilunar valves), marking the end of the systole.