Related Experiment Video
Updated: Sep 28, 2026

Dynamic Electrochemical Measurement of Chloride Ions
Published on: February 5, 2016
A multivariate approach to amperometric free chlorine monitoring: calibration, interference compensation, and
Guglielmo Emanuele Franceschi1, Lisa Rita Magnaghi1,2, Gian Paolo Quarta3
1Department of Chemistry, University of Pavia Viale Taramelli 12 Pavia PV 27100 Italy lisarita.magnaghi@unipv.it.
Abstract:
Reliable monitoring of Free Available Chlorine (FAC) in drinking water is essential for ensuring disinfection efficiency and detecting contamination events, yet in situ amperometric measurements remain strongly affected by matrix variability and long-term instability. In this work, we present an optimized amperometric protocol for FAC determination implemented in NEMO, a low-cost, battery-powered Online Water Quality Monitoring (OWQM) device designed for continuous operation in water distribution systems. The working potential was identified through cyclic voltammetry and subsequently optimized using a multivariate Design of Experiments (DoE) approach. To address the strong dependence of the amperometric signal on pH and conductivity, two Multiple Linear Regression calibration strategies were developed: an in silico calibration model (Approach A) and a direct multivariate model (Approach B). Both approaches were built on 125 calibration samples and validated on an independent test set, showing a consistent agreement with the reference DPD spectrophotometric method. Limits of detection were evaluated through four complementary procedures, confirming suitability for typical FAC levels in drinking water. Field deployment on six devices over two months demonstrated overall stable performance, limited hysteresis, and reliable tracking of temporal FAC variations. The proposed methodology enables robust semi-quantitative chlorine monitoring in real networks and represents a scalable solution for distributed early-warning systems in water quality management.
Related Concept Videos
Amperometry: Overview
Controlled-Current Coulometry: Overview
Controlled-Potential Coulometry: Electrolytic Methods
The chosen potential ensures...
Controlled-Current Coulometry: Coulometric Titration
The fundamental requirements for coulometric titrations are (1) 100% efficiency in the reagent-generating electrode reaction and (2) a stoichiometric and preferably rapid reaction between the generated...
Interfacial Electrochemical Methods: Overview
Atomic Absorption Spectroscopy: Interference
Spectral interference occurs when signals from other elements or molecules overlap with the analyte signal, falsely elevating or masking the analyte's absorbance. This interference can be corrected using Zeeman,...