Related Experiment Video
Updated: Aug 10, 2025

Colorimetric Detection of Bacteria Using Litmus Test
Published on: September 17, 2016
Chemometric-Assisted Litmus Test: One Single Sensing Platform Adapted from 1-13 to Narrow pH Ranges
Lisa Rita Magnaghi1,2, Giancarla Alberti1, Camilla Zanoni1
1Department of Chemistry, University of Pavia, Via Taramelli 12, 27100 Pavia, Italy.
A new chemometric-assisted litmus test (CLT) uses pH indicators on EVOH for accurate pH measurements across wide and narrow ranges. This simple, rapid method offers reliable results with errors under 0.5 pH units.
Area of Science:
- Analytical Chemistry
- Materials Science
Background:
- Accurate pH determination is crucial in various scientific fields.
- Existing methods can be complex or time-consuming.
- Development of user-friendly and reliable sensing platforms is needed.
Purpose of the Study:
- To develop a novel colorimetric sensing platform for pH determination.
- To create a device capable of measuring pH across a broad range (1-13) and specific narrow ranges.
- To validate the accuracy and reliability of the developed sensing platform.
Main Methods:
- Covalent anchoring of commercial pH indicators to ethylene vinyl alcohol (EVOH) to create a 3x4 colorimetric sensing array.
- Utilizing chemometric techniques, including Principal Component Analysis (PCA) and Partial Least Square Regression (PLS), for data analysis.
- Acquiring images of the sensing platform using a camera for quantitative analysis of RGB indices.
Main Results:
- The developed chemometric-assisted litmus test (CLT) platform enables pH determination from 1 to 13.
- The sensing platform achieves high accuracy with errors below 0.5 pH units.
- The experimental procedure is simple, quick, and reliable, with equilibration achieved in under 2 hours.
Conclusions:
- The chemometric-assisted litmus test (CLT) is a novel, effective, and reliable colorimetric sensing platform for pH determination.
- The platform offers a simple and rapid alternative for accurate pH measurements in diverse applications.
- The integration of chemometric analysis enhances the quantitative capabilities of the colorimetric sensor.
Related Concept Videos
Indicators
Titration of a Weak Acid with a Weak Base
As a result, there is no simple...
Titration Calculations: Weak Acid - Strong Base
For the titration of 25.00 mL of 0.100 M CH3CO2H with 0.100 M NaOH, the reaction can be represented as:
Titration of Polyprotic Base with a Strong Acid
Titration of a Weak Base with a Strong Acid
Using the ICE table and substituting the Kb value, we calculate the initial pH of 50 mL of 0.1 M ammonia to be 11.11. Addition of 25 mL of 0.1 M hydrochloric acid to this solution of ammonia results in a buffer with an equal concentration of ammonia and ammonium ions. The pH of this buffer can be calculated by substituting these...
Determining the pH of Salt Solutions

