X-ray image quality before and after radiographer commenting: A quantitative visual grading characteristics analysis
1Medical Image Optimisation and Perception Group, Discipline of Medical Imaging Science, Susan Wakil Health Building, Western Ave, Camperdown, NSW, 2050, Australia.
Introduction:
The Radiographer Comment and Alert (RCA) model was established to provide written alerts of abnormal radiographic appearances identified at acquisition, but its quantitative impact on image quality is unknown. This study quantifies differences in radiograph image quality before and after RCA implementation.
Methods:
A total of 234 radiographs encompassing the pelvis, hand, wrist, elbow, knee, ankle, and foot were collected. This comprised all 117 investigations for these anatomical areas with radiographer comments over 12-months at one site, and 117 matched radiographs obtained one year before RCA implementation. Each image pair was displayed simultaneously, but the order and left-right orientation was randomised. Seventeen radiographers independently rated image pairs using a visual grading characteristics (VGC) analysis scale on seven quality criteria (rotation, angulation, centering, collimation, exposure, artifacts, diagnostic utility). Data were analysed using VGC Analyser Software v1.0.2. Non-parametric rank-invariant statistics generated an area under the VGC curve (AUCVGC) to measure the difference in quality between images with and without radiographer comments.
Results:
Across the combined dataset, images acquired after implementation of RCA received visual grading ratings for radiological quality that were significantly higher than images acquired prior to implementation (AUCVGC0.52, p = 0.016, CI[0.500862,0.532967]). Statistical significance at 95% confidence was not met for individual upper (AUCVGC0.52, p = 0.084) and lower limb (AUCVGC0.50, p = 0.746) regions, but was achieved for the axial region (AUCVGC0.54, p = 0.012). Quality improvement was driven by improved positioning, particularly rotation (AUCVGC0.57, p = 0.002). Intraclass correlation coefficient scores were good or excellent (ICC3,k ≳ 0.62-0.97) and all reached significance (p-value<0.05), indicating stable consensus and good inter-rater agreement.
Conclusion:
Quantitative evidence demonstrates implementation of RCA significantly improves the overall quality of projection radiographs submitted for reporting.
Implications For Practice:
Radiographer image interpretation models can be utilised as tools to improve radiographic image quality.
Related Concept Videos
X-ray Imaging
Radiological Investigation I: X-ray and CT
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...
Imaging Studies III: Computed Tomography