Related Experiment Video
Updated: Oct 18, 2026

Polarization and Characterization of M1 and M2 Human Monocyte-Derived Macrophages on Implant Surfaces
Published on: December 6, 2024
Catalytic MXene implant interfaces reprogram radiation-induced foreign body response to prevent capsular contracture
Yusi Zhang1, Zhongxue Lin2, Yifan Qiao1
1Department of Medical Oncology, The First Affiliated Hospital of Xi'an Jiaotong University, Shaanxi, 710061, PR China; Department of Cancer Center, The First Affiliated Hospital of Xi'an Jiaotong University, Shaanxi, 710061, PR China; Precision Medicine Center, The First Affiliated Hospital of Xi'an Jiaotong University, Shaanxi, 710061, PR China.
Abstract:
Radiotherapy markedly exacerbates foreign body response (FBR) to silicone implants, driving capsular fibrosis and contracture, yet actionable interfacial mechanisms remain insufficiently defined. Here, we engineer an implant-centered Ti3C2Tx MXene-modified PDMS coating (APM) to modulate the redox microenvironment at the tissue-implant interface to reprogram radiotherapy-induced FBR. Oxygen plasma activation and 3-aminopropyltriethoxysilane (APTES) silanization enable covalent anchoring of single-layer MXene nanosheets onto PDMS, yielding a conformal APM film with enhanced hydrophilicity, preserved layered MXene architecture, enzyme-mimicking ROS-scavenging activity, and excellent cytocompatibility. Transcriptomic profiling guides the study, revealing the coordinated downregulation of inflammatory and extracellular matrix remodeling pathways. Mechanistically, interfacial redox regulation dampens NF-κB signaling and reduces endothelial ICAM-1 expression, thereby limiting monocyte adhesion and downstream inflammatory amplification. A tri-culture endothelial-macrophage-fibroblast model further demonstrates that MXene interfaces disrupt pro-inflammatory crosstalk and inhibit myofibroblast activation. In a murine peri-implant irradiation model, APM-coated implants preserve a CD31+/ICAM-1-low microvasculature, reduce peri-implant pro-inflammatory macrophage accumulation, and significantly decrease capsular thickness and collagen deposition. Collectively, these findings demonstrate that MXene-based catalytic coatings can disrupt the positive feedback loop between radiation injury and fibrotic capsule formation, offering a mechanistically grounded strategy to mitigate implant-associated fibrosis.
More Related Videos
12:19Multi-Scale Modification of Metallic Implants With Pore Gradients, Polyelectrolytes and Their Indirect Monitoring In vivo
Published on: July 1, 2013
08:38Renal Capsule Xenografting and Subcutaneous Pellet Implantation for the Evaluation of Prostate Carcinogenesis and Benign Prostatic Hyperplasia
Published on: August 28, 2013