Introduction:
Intraocular pressure (IOP) is the primary biomarker for the diagnosis and management of glaucoma, a progressive optic neuropathy and the second leading cause of blindness worldwide. Its pathophysiology involves an imbalance between aqueous humor production and drainage that elevates IOP, ultimately damaging the optic nerve. IOP exhibits substantial circadian fluctuations, and single-point clinical measurements frequently fail to capture peak diurnal pressure, thereby underestimating the risk of disease progression, delaying necessary intervention, and obscuring patient compliance with pharmaceutical therapies.
Areas Covered:
This review synthesizes historical, contemporary, and emerging IOP measurement technologies, examining their underlying physical principles, clinical utility, and limitations, with particular emphasis on their capacity to characterize the dynamic, time-varying nature of IOP. The search drew on Google Scholar and manufacturers' websites, focusing on physical principles and systems not yet FDA-approved or clinically tested.
Expert Opinion:
A critical unmet clinical need exists for accessible home-monitoring solutions. The ideal device would be non-invasive, affordable, and user-friendly, requiring neither topical anesthesia nor sterilization, and would support remote data transmission to facilitate continuous patient-clinician communication. This unmet need offers an opportunity for engineers and healthcare professionals to develop new technologies to help people avoiding travels to and decongest doctors' offices.
Related Concept Videos
Increased Intracranial Pressure l: Introduction
Measurement of Blood Pressure
Glaucoma: Overview
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessment of blood pressure in brachial artery(two-step method)
Pressure Gauges