Related Experiment Video
Updated: Oct 27, 2026

Façade-Level Monitoring of CO2 Variability under Urban Heat Island Conditions using Low-Cost Sensor Data Loggers
Published on: December 12, 2025
From Retrofitting to Adaptive Fitting: Time Scale and Locus of Change Capacity in Adaptive and Demountable Building
1Department of Architecture, TOBB University of Economics and Technology, 06560 Ankara, Türkiye.
Abstract:
Building envelopes are addressed by two largely separate bodies of research: adaptive façade design, which treats change as behaviour during operation, and design for disassembly, which treats it as an end-of-life property. This study asks whether that separation reflects a division in the problem or in academic labour. Four modes of intervention through which envelopes are kept fit (add-on, replace, cover it, and wrap it) are mapped onto four fitting modes of natural skin; the correspondence weakens as the intervention becomes more external. Fifteen documented cases are then coded against a scheme separating the time scale at which change is accommodated from the location and type of the capacity accommodating it, with predictions recorded before coding. Every biomimetic case operates at daily or seasonal scale, and fourteen of fifteen cases return a functioning envelope when their adaptive capacity is removed. Cases addressing life-cycle change do so through external agency, and none has undergone the change it anticipates. No case addresses the intermediate scale of years to decades, at which buildings in fact become unfit. The unoccupied combination is termed adaptive fitting here, and the argument advanced is that the obstacle is evaluation before capability: envelopes are assessed on how they behave, not on how long they continue to behave that way.
Related Concept Videos
Design Example: Sustainability in Concrete Building
There are multiple approaches to achieve sustainability in a commercial concrete building. For instance, construct a concrete parking area under the building, utilizing pervious concrete paver blocks in open areas to facilitate rainwater collection through an underground cistern.
Expansion and Contraction in Masonry Walls
To...
Design Example: Dimensioning of Concrete Masonry Construction
The site engineer has laid out a plan for the storeroom with external dimensions of twelve feet in length and eight feet...
Masonry Curtain Walls
Design Example: Analyzing Capacity Contours for Flood Risk Assessment
Internal Loadings in Structural Members: Problem Solving
To illustrate this, let's consider a beam OC of 5 kN, inclined at an angle of 53.13° with the horizontal and supported at both ends. Determine the internal loadings...