Related Experiment Video
Updated: Oct 28, 2026

Enhancing Upper Limb Function and Motor Skills Post-Stroke Through an Upper Limb Rehabilitation Robot
Published on: September 6, 2024
Multimodal Feedback-Enhanced Soft Hand Rehabilitation Robot: System Development and Preliminary Clinical Evaluation
Jianwei Lai1, Aiguo Song1, Xuemei Fan2
1The State Key Laboratory of Digital Medical Engineering, Jiangsu Key Lab of Remote Measurement and Control, School of Instrument Science and Engineering, Southeast University, Nanjing 210096, China.
Abstract:
Soft robotic systems have attracted increasing attention for hand rehabilitation because of their compliance, adaptability, and potential for comfortable human-robot interaction. However, the clinical translation of soft hand rehabilitation robots remains limited by insufficient integration of interactive training, user feedback, and practical wearability. This study presents a multimodal feedback-enhanced soft hand rehabilitation robot based on lattice-structured soft pneumatic actuators (LSPAs), together with a preliminary clinical evaluation. The system integrates a fabric-based soft glove, pneumatic actuation, fingertip force sensing, hand-motion tracking, and interactive virtual rehabilitation tasks to provide coordinated visual, auditory, force-related, and mirror-visual feedback. Material characterization was first conducted to compare three TPU materials with different mechanical properties, followed by system-level evaluation of usability, wearability, and actuator durability. A four-week robot-assisted rehabilitation intervention was then conducted in nine stroke survivors. Participants completed five one-hour sessions per week, including passive training and multimodal interactive training. Clinical outcomes were evaluated using the Brunnstrom motor recovery stage, Fugl-Meyer Assessment of the upper extremity (FMA-UE), National Institutes of Health Stroke Scale (NIHSS), and Activities of Daily Living (ADL) scale, while usability was assessed using the System Usability Scale (SUS). After four weeks, the mean Brunnstrom stage increased from 2.44±2.07 to 3.67±2.12, FMA-UE increased from 18.33±25.63 to 32.67±23.11, NIHSS decreased from 5.67±4.36 to 3.22±2.99, and ADL increased from 49.78±39.53 to 66.67±22.50. The mean SUS score was 74.4. TPU420D provided the best durability among the tested configurations, with more than 30 h of recorded use without failure during the experimental period. These findings support the feasibility and usability of the proposed system and provide preliminary evidence for its application in stroke hand rehabilitation. Because of the small sample size, heterogeneous post-stroke status, short intervention period, and absence of a control group, the clinical findings should be interpreted as preliminary rather than confirmatory evidence of therapeutic efficacy.
More Related Videos
06:44Development of a Novel Task-oriented Rehabilitation Program using a Bimanual Exoskeleton Robotic Hand
Published on: May 20, 2020
07:34Functional MRI in Conjunction with a Novel MRI-compatible Hand-induced Robotic Device to Evaluate Rehabilitation of Individuals Recovering from Hand Grip Deficits
Published on: November 23, 2019