A Simple Stimulatory Device for Evoking Point-like Tactile Stimuli: A Searchlight for LFP to Spike Transitions
Published on: March 25, 2014
Amplitude and fall-time discrimination of unit spike activity using TTL
Brain Research Bulletin
|January 1, 1979
Summary
A new, affordable window discriminator using TTL integrated circuits reliably separates signal spikes by amplitude or fall-time. This electronic device allows for simultaneous analysis of two spikes with visual feedback for easy setup.
Area of Science:
- Electronics
- Signal Processing
- Instrumentation
Background:
- Accurate signal spike analysis is crucial in various scientific and engineering fields.
- Existing methods for spike discrimination can be complex or expensive.
Purpose of the Study:
- To describe the construction and function of an inexpensive and reliable window discriminator.
- To enable discrimination of signal spikes based on amplitude and/or fall-time.
- To facilitate simultaneous analysis of two separate spikes.
Main Methods:
- Construction of a window discriminator utilizing Transistor-Transistor Logic (TTL) integrated circuits.
- Implementation of amplitude-based and amplitude-and-fall-time-based discrimination criteria.
- Development of simultaneous analysis capabilities for two distinct spikes.
- Integration of visual display for pulse outputs and window parameters.
Main Results:
- The described device reliably discriminates between unit spikes based on selected amplitude and/or fall-time parameters.
- Simultaneous analysis of two separate spikes is achievable with the constructed discriminator.
- Visual display of outputs and window settings simplifies the setup and calibration process.
Conclusions:
- An economical and dependable window discriminator can be built using standard TTL integrated circuits.
- The device offers versatile spike discrimination capabilities suitable for various applications.
- Direct visual control enhances the usability and precision of the instrument.
More Related Videos
Related Concept Videos
Tandem Mass Spectrometry
Tandem mass spectrometry is a technique that uses multiple mass analyzers in series to obtain a higher selectivity and reduce chemical noise during analyte detection. Instruments with multiple analyzers separated by an interaction cell enable secondary fragmentation and selected study of the fragment ions.Secondary fragmentations occur in the interaction cell and can be induced by various factors. Fragmentation induced by collision with inert gases, such as N2, Ar, He, etc., is called...
Basic Discrete Time Signals
The unit step sequence is defined as 1 for zero and positive values of the integer n. This sequence can be graphically displayed using a set of eight sample points, showing a step function starting from n=0 and remaining constant thereafter.
The unit impulse or sample sequence is mathematically expressed as zero for all n values except at n=0, where it is one. The unit impulse sequence, denoted by δ(n), is the first difference of the unit step sequence, while the unit step sequence u(n) is the...
The unit impulse or sample sequence is mathematically expressed as zero for all n values except at n=0, where it is one. The unit impulse sequence, denoted by δ(n), is the first difference of the unit step sequence, while the unit step sequence u(n) is the...