Related Experiment Videos
Carbon monoxide: a hazard to fire fighters
Archives of Environmental Health
|July 1, 1979
Summary
Firefighters face significant carbon monoxide exposure, with levels reaching 3,000 ppm. This occupational hazard, especially in two-story buildings, may contribute to the high incidence of heart disease in firefighters.
Area of Science:
- Occupational Health
- Environmental Science
- Toxicology
Background:
- Firefighters are regularly exposed to combustion byproducts.
- Carbon monoxide (CO) is a primary toxic gas produced during fires.
- Understanding CO exposure levels is crucial for firefighter safety and health.
Purpose of the Study:
- To quantify carbon monoxide (CO) exposure levels experienced by firefighters during structural fires.
- To identify factors influencing CO concentrations in fire environments.
- To assess the potential health risks associated with firefighter CO exposure.
Main Methods:
- Carbon monoxide levels were measured in 25 fires in Los Angeles.
- CO concentrations were recorded during active firefighting operations.
- Observations included smoke density and location of highest CO levels.
Main Results:
- CO levels varied significantly, with some fires reaching up to 3,000 ppm.
- Elevated CO levels ( > 100 ppm) often correlated with heavy, noxious smoke.
- In two-story structures, the second floor showed the highest CO concentrations, persisting even after the fire was suppressed.
Conclusions:
- Firefighters are exposed to hazardous levels of carbon monoxide during fire incidents.
- CO exposure may be a contributing factor to the elevated rates of heart disease observed in the firefighting profession.
- Further research and protective measures are warranted to mitigate CO risks for firefighters.