Effects of sample-diluent interactions on surface tension and pressures in continuous flow manifolds
Clinica Chimica Acta; International Journal of Clinical Chemistry
|November 15, 1979
Abstract:
When a plasma sample is aspirated into a continuous flow analyser the internal pressure of the manifold increases. The pressure change is the result of insufficient detergent present to bind all the protein in the sample, and is a potential source of inaccuracy and imprecision in the assay. It is recommended that Brij 35 be used at a concentration 10 times above the binding capacity of the albumin in the sample, to minimise changes in pressure between samples.
Related Concept Videos
Surface Tension, Capillary Action, and Viscosity
Surface Tension
The various IMFs between identical molecules of a substance are examples of cohesive forces. The molecules within a liquid are surrounded by other molecules and are attracted equally in all directions by the cohesive forces within the liquid. However, the molecules on the surface of a liquid are attracted only by about one-half as many molecules. Because of the unbalanced molecular attractions on the surface molecules, liquids contract to form a shape that minimizes the number...
The various IMFs between identical molecules of a substance are examples of cohesive forces. The molecules within a liquid are surrounded by other molecules and are attracted equally in all directions by the cohesive forces within the liquid. However, the molecules on the surface of a liquid are attracted only by about one-half as many molecules. Because of the unbalanced molecular attractions on the surface molecules, liquids contract to form a shape that minimizes the number...
Excess Pressure Inside a Drop and a Bubble
The shape of a small drop of liquid can be considered spherical, neglecting the effect of gravity. This drop can further be considered as two equal hemispherical drops put together due to surface tension. The forces acting on the spherical drop are due to the pressure of the liquid inside the drop, the pressure due to air outside the drop, and the force due to the surface tension acting on the two hemispherical drops.
Surface Tension of Fluid
Surface tension is a fundamental property of fluids, occurring at the boundary between a liquid and a gas or between two immiscible liquids. This phenomenon arises from the cohesive forces between molecules at the fluid's surface, creating an effect similar to a stretched elastic membrane. Inside each fluid, molecules are equally attracted in all directions by neighboring molecules, but surface molecules experience a net inward force, resulting in surface tension.
Surface tension varies with...
Surface tension varies with...
Continuity Equation
The continuity equation asserts that the mass flow rate must remain constant for a steady flow of an incompressible fluid within a confined system. This principle applies to systems where fluid passes through varying cross-sectional areas, such as nozzles, syringes, and pipes.
The mass flow rate is expressed as:
The mass flow rate is expressed as:
Typical Model Studies
Fluid mechanics model studies often utilize scaled-down systems to predict fluid behavior in full-scale environments, such as river flows, dam spillways, and structures interacting with open surfaces. Maintaining Froude number similarity in river models is crucial, as it replicates surface flow features like wave patterns and velocities.
Turbulent Flow: Problem Solving
Carbonation is a process used to dissolve carbon dioxide gas in a liquid, commonly used in the production of carbonated beverages. Achieving efficient carbonation requires careful control of temperature, pressure, and flow conditions. By adjusting these parameters, carbonation efficiency can be maximized, producing a higher concentration of CO2 in the liquid.
Temperature is a key factor in CO2 solubility. In this case, the CO2 gas and the liquid are cooled to 20°C. Lower temperatures enhance...
Temperature is a key factor in CO2 solubility. In this case, the CO2 gas and the liquid are cooled to 20°C. Lower temperatures enhance...