Related Experiment Video
Updated: Aug 15, 2026

Use of a Hanging-weight System for Isolated Renal Artery Occlusion
Published on: July 19, 2011
Computed tomography of experimental acute renal ischemia
Abstract:
The potential role of computed tomography (CT) in the detection of acute renal ischemia was assessed in nine mongrel dogs. Ischemia was produced by inflation of a balloon catheter in the main renal artery, with scans performed before, during, and after a 60-minute period of ischemia. A small but consistent increase in the attenuation value of ischemic renal parenchyma was observed. When intravenous contrast material was given, the ischemic kidney was markedly less enhanced than the contralateral, nonischemic kidney. By using the contralateral kidney for comparison, the ischemic kidney could be identified with or without the use of a contrast agent. Although calculations of mean pixel values were necessary when a contrast agent was not injected, the abnormal kidney could be easily recognized from the CT images themselves when intravenous contrast material was given. Because of the consistency with which the abnormalities were observed, we recommend a clinical trial of CT in suspected acute renal ischemia.
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies for Cardiovascular System V: CT
Imaging Studies III: Computed Tomography
Imaging Studies VII: Vascular Imaging