The use of lyophilized vein grafts in vascular access for chronic hemodialysis
Artificial Organs
|August 1, 1979
Abstract:
The feasibility of utilizing lyophilized veins for creation of A-V fistulas was examined in two studies. In Study I, the longevity of lyophilized vein fistulas was found to be comparable to that of fresh veins in the experimental animal. Study II showed that lyophilized cadaveric veins performed at least as well as bovine grafts when used for vascular access in chronic hemodialysis patients. The advantages of lyophilized veins for creation of A-V fistulas in dialysis patients are described.