Evaluation of the Schirmer tear test
Summary
The Schirmer filter paper test is unreliable for measuring tear production in women, showing wide result variations even in the same individuals over consecutive days.
Area of Science:
- Ophthalmology
- Ocular Surface Disease
- Tear Film Research
Background:
- Accurate measurement of tear production is crucial for diagnosing and managing dry eye disease.
- The Schirmer test is a commonly used method for assessing tear secretion.
- Variability in test results can impact clinical diagnosis and research findings.
Purpose of the Study:
- To evaluate the reliability of the Schirmer filter paper test for measuring tear production.
- To assess the day-to-day variability of tear production measurements in healthy women.
- To determine if local anesthetic drops affect the reliability of the Schirmer test.
Main Methods:
- 10 healthy women participated in the study.
- Tear production was measured using the Schirmer filter paper test.
- Measurements were taken daily for 30 or 31 consecutive days after instillation of local anesthetic drops.
Main Results:
- The Schirmer test demonstrated significant variability in tear production measurements within the same subjects.
- Many participants exhibited results that, by standard interpretation, indicated inadequate tear production.
- Day-to-day fluctuations in tear production were observed even under controlled conditions.
Conclusions:
- The Schirmer filter paper test is not a reliable indicator of tear production.
- High variability suggests potential limitations in its diagnostic accuracy for dry eye.
- Further research is needed to explore more consistent methods for tear production assessment.