Related Experiment Video
Updated: Aug 15, 2026

Electromagnetic Navigation Transthoracic Nodule Localization for Minimally Invasive Thoracic Surgery
Published on: May 4, 2022
111Indium-bleomycin breast and axilla imaging
111Indium-Bleomycin (111In-Blm), a new radiopharmaceutical, was administered intravenously to 37 patients with benign and malignant breast lesions. Early and delayed images of both the breasts and axillae were made, and results were correlated with physical examination, histopathology of the excised lesion, mammography, and thermography. In 18 patients with malignant disease, clinical examination of the breast and axilla correlated with histopathology in 78 and 54% of the cases, respectively. Images of the breast were accurate (true positives) in 83% of the cases. Images of the axilla were accurate in 62% of the cases. Mammography was correct and suggested malignancy in 88%, and thermography in 73% of the cases. In 19 patients with benign breast lesions, clinical examination of the breast and axilla correlated with histopathology in 68 and 95% of the cases, respectively. Scans of the breast and axilla were correct (true negative) 79 and 95% of the time, respectively. Mammography was correct, and suggested benignancy, in 53% and thermography in 25% of the cases. Imaging of the breasts using 111In-Blm appears to be as accurate as physical examination and mammography for palpable benign and malignant breast tumors. It is less accurate than mammography for microscopic malignancies. Axillary imaging does not appear to be worthwhile because many axillary metastases are too small for detection with current nuclear medicine instrumentation.
111Indium-Bleomycin (111In-Blm), a new radiopharmaceutical, was administered intravenously to 37 patients with benign and malignant breast lesions. Early and delayed images of both the breasts and axillae were made, and results were correlated with physical examination, histopathology of the excised lesion, mammography, and thermography. In 18 patients with malignant disease, clinical examination of the breast and axilla correlated with histopathology in 78 and 54% of the cases, respectively. Images of the breast were accurate (true positives) in 83% of the cases. Images of the axilla were accurate in 62% of the cases. Mammography was correct and suggested malignancy in 88%, and thermography in 73% of the cases. In 19 patients with benign breast lesions, clinical examination of the breast and axilla correlated with histopathology in 68 and 95% of the cases, respectively. Scans of the breast and axilla were correct (true negative) 79 and 95% of the time, respectively. Mammography was correct, and suggested benignancy, in 53% and thermography in 25% of the cases. Imaging of the breasts using 111In-Blm appears to be as accurate as physical examination and mammography for palpable benign and malignant breast tumors. It is less accurate than mammography for microscopic malignancies. Axillary imaging does not appear to be worthwhile because many axillary metastases are too small for detection with current nuclear medicine instrumentation.
Related Concept Videos
Radiological Investigation I: X-ray and CT
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...

