Sonographically guided transperineal prostatic biopsy: preliminary experience with a longitudinal linear-array

M D Rifkin, A B Kurtz, B B Goldberg

    AJR. American Journal of Roentgenology
    |April 1, 1983
    PubMed
    Summary

    Transperineal prostate biopsy using continuous sonographic monitoring improved accuracy in diagnosing prostate cancer. This real-time rectal endoscopic probe technique enhanced needle visualization for better sample collection in suspected cases.

    Related Concept Videos

    You might also read

    Related Articles

    Articles linked to this work by shared authors, journal, and citation graph.

    Sort by
    Same author

    Guidelines and good clinical practice recommendations for contrast enhanced ultrasound (CEUS) in the liver--update 2012: a WFUMB-EFSUMB initiative in cooperation with representatives of AFSUMB, AIUM, ASUM, FLAUS and ICUS.

    Ultraschall in der Medizin (Stuttgart, Germany : 1980)·2012
    Same author

    High-throughput detection and sizing of individual low-index nanoparticles and viruses for pathogen identification.

    Nano letters·2010
    Same author

    Subsurface microscopy of integrated circuits with angular spectrum and polarization control.

    Optics letters·2009
    Same author

    Applications of optical resonance to biological imaging and label-free protein microarrays.

    Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference·2009
    Same author

    Analysis and classification of tissue with scatterer structure templates.

    IEEE transactions on ultrasonics, ferroelectrics, and frequency control·2008
    Same author

    Strong extinction of a far-field laser beam by a single quantum dot.

    Nano letters·2007

    Area of Science:

    • Urology
    • Medical Imaging
    • Oncology

    Background:

    • Prostate cancer diagnosis often relies on biopsies.
    • Accurate needle placement is crucial for effective biopsy.
    • Limitations exist in conventional digital guidance for prostate biopsies.

    Purpose of the Study:

    • To evaluate the efficacy of transperineal prostate biopsy with continuous sonographic monitoring.
    • To assess the accuracy of sonographic guidance compared to digital guidance.

    Main Methods:

    • Transperineal prostate biopsy was performed in 25 patients with suspected prostate disease.
    • Continuous sonographic monitoring utilized a real-time rectal endoscopic probe with a longitudinal linear array.
    • Needle visualization from the perineum into the prostate was achieved.

    Related Experiment Videos

    Main Results:

    • Sonographic guidance provided more accurate biopsy of clinically suspected nodules in 13 patients compared to digital guidance.
    • Subclinical prostate carcinomas were identified and biopsied in three patients.
    • Areas of atypical histology were also identified and biopsied in three patients.

    Conclusions:

    • Continuous sonographic monitoring during transperineal prostate biopsy enhances diagnostic accuracy.
    • This technique improves the detection of clinically significant prostate nodules and subclinical disease.
    • Sonographic guidance represents an advancement in prostate biopsy procedures.