Comparison of dieldrin, lindane, and DDT extractions from serum, and gas-liquid chromatography using glass capillary columns
Related Experiment Video
Updated: Oct 20, 2026

Laboratory Estimation of Net Trophic Transfer Efficiencies of PCB Congeners to Lake Trout (Salvelinus namaycush) from Its Prey
Published on: August 29, 2014
Abstract:
Rats were given an oral dose of 14C-labeled chlorinated pesticides to obtain serum containing p,p'-DDT, dieldrin, or lindane. Simple hexane and formic acid-hexane extraction methods, involving pretreatment of the serum with formic acid, were compared by radiometric and by paper chromatographic and gas chromatographic analysis. In vivo binding of chlorinated pesticides to constituents of the serum does not necessarily prohibit their isolation by simple hexane extractions, provided that the extraction is very vigorous and at least 5 min long. Stable emulsions were broken by cooling in liquid nitrogen or Dry Ice-acetone. The hexane extraction method described yields quantitative recovery of the pesticides studied, whereas the formic acid-hexane method is quantitative for p,p'-DDT, 93% for dieldrin, and 89% for lindane. Gas chromatographic comparison of both methods, using human serum, shows that the hexane method extracts 16% more beta-BHC, 7% more dieldrin and HCB, and 4% more p,p'-DDE from serum than does the formic acid-hexane method. The difference for p,p'-DDT is not significant. Gas chromatography with glass capillary columns and an all-glass solids injection system yielded detection limits as low as 15 fg. Data show that the use of an internal standard considerably improves the precision of quantitation.
Related Concept Videos
Silica Gel Column Chromatography: Overview
Polar components tend to bind strongly to the silica gel, causing them to move slowly through the column. In contrast, nonpolar compounds...
Types Of Column Chromatography
Gel Filtration Chromatography
When the...
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a column.
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...