Related Experiment Videos
A radiolabeled antiglobulin test for crossmatching platelet transfusions
Blood
|February 1, 1983
Summary
A new radiolabeled antiglobulin test improves platelet crossmatching for alloimmunized patients. This radioactivity antiglobulin test (RAGT) helps select compatible platelets, reducing transfusion failures in refractory patients.
Area of Science:
- Immunology
- Transfusion Medicine
- Hematology
Background:
- Alloimmunized patients often experience platelet transfusion failures despite HLA-matched platelets.
- Refractory patients require improved methods for selecting compatible platelet transfusions.
Purpose of the Study:
- To evaluate a radiolabeled antiglobulin technique for platelet crossmatching in alloimmunized patients.
- To determine if the radioactivity antiglobulin test (RAGT) can predict transfusion success.
Main Methods:
- A 125I-labeled goat anti-human IgG indirect Coombs test was used for platelet crossmatching.
- The radioactivity antiglobulin test (RAGT) index was calculated to assess compatibility.
- Transfusion effectiveness was measured by corrected platelet count increment (CCI) at 1 and 20 hours in 19 refractory patients.
Main Results:
- Platelet transfusions with a RAGT index ≤ 1.9 showed significantly higher mean CCI at 1 hour (17,570/cu mm) and 20 hours (8,722/cu mm) compared to those with an index ≥ 2.0 (4,237/cu mm at 1 hr, 571/cu mm at 20 hr).
- One false negative and nine cases with good initial increments but zero survival at 20 hours were observed.
- The RAGT demonstrated a strong correlation between crossmatch results and transfusion outcomes.
Conclusions:
- The radiolabeled antiglobulin technique is a valuable tool for selecting compatible platelets in refractory, alloimmunized patients.
- This method aids in reducing platelet transfusion failures by identifying incompatible units.