Related Experiment Video
Updated: Aug 10, 2026

Non-invasive Optical Measurement of Cerebral Metabolism and Hemodynamics in Infants
Published on: March 14, 2013
Simultaneous transcutaneous carbon dioxide and transcutaneous oxygen monitoring in neonatal intensive care
Abstract:
Continuous transcutaneous carbon dioxide partial pressure (tc PCO2) and continuous transcutaneous oxygen partial pressure (tc PO2) was monitored simultaneously in 10 consecutive neonatal intensive care patients treated for respiratory problems or immaturity. During measurement the electrode temperature was 44 degrees C while during the resting periods--with the electrodes left in situ--the electrode temperature was 37 degrees C. Measurements were performed for periods up to 31 hours. It was possible to discover changes in central blood gas partial pressures also at the lower electrode temperature. This was especially true for the tc PCO2 recording which was less influenced by the decrease in electrode temperature than the tc PO2 recording. In six patients an increased frequency of apnoea was diagnosed by the transcutaneous blood gas monitoring equipment previous to other clinical signs. A statistically highly significant correlation was found between transcutaneous and arterial blood gas values, the arterial samples obtained from umbilical artery catheters. tc PCO2 and tc PO2 very sensitively reacts to changes in the breathing pattern and to changes in activity of the neonate emphasizing the drawbacks of previous blood gas monitoring techniques. The technique for continuous transcutaneous carbon dioxide monitoring is ready for clinical use and is a valuable additional tool in all neonatal intensive care patients with the risk of alveolar hypoventilation.
Related Concept Videos
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac muscle...
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this principle...
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is important.
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...