Respiratory flow integrator with improved stability.

N S Deno, H L Barlett, E R Buskirk

    Journal of Applied Physiology: Respiratory, Environmental and Exercise Physiology
    |April 1, 1978
    PubMed
    Summary
    This summary is machine-generated.

    Related Concept Videos

    You might also read

    Related Articles

    Articles linked to this work by shared authors, journal, and citation graph.

    Sort by
    Same author

    Equipment Update: Penn State's Foldable Rigid Stretcher.

    The Physician and sportsmedicine·2017
    Same author

    Injury Rates in Women Joggers.

    The Physician and sportsmedicine·2016
    Same author

    Effects of high and low humidity on heat exchanges of lightly clothed men.

    Technical report, CP. Quartermaster Research & Development Center (U.S.). Chemicals and Plastics Division·2014
    Same author

    Effect of continuous cold exposure on nocturnal body temperature of man.

    Technical report, CP. Quartermaster Research & Development Center (U.S.). Chemicals and Plastics Division·2014
    Same author

    Commentaries.

    Canadian Medical Association journal·2010
    Same author

    Commentaries.

    Canadian Medical Association journal·2010
    Same journal

    Metabolic control of cardiac output response to exercise in McArdle's disease.

    Journal of applied physiology: respiratory, environmental and exercise physiology·1984
    Same journal

    Hypoxic insomnia: effects of carbon monoxide and acclimatization.

    Journal of applied physiology: respiratory, environmental and exercise physiology·1984
    Same journal

    Quiet-breathing vs. panting methods for determination of specific airway conductance.

    Journal of applied physiology: respiratory, environmental and exercise physiology·1984
    Same journal

    A new method for raising neonatal rabbits in a hypoxic environment.

    Journal of applied physiology: respiratory, environmental and exercise physiology·1984
    Same journal

    Modification of the cutaneous vascular response to exercise by local skin temperature.

    Journal of applied physiology: respiratory, environmental and exercise physiology·1984
    Same journal

    Temperature regulation during treadmill exercise in the rat.

    Journal of applied physiology: respiratory, environmental and exercise physiology·1984
    See all related articles

    A new circuit accurately integrates respiratory flow signals into volume signals with less than 1% error. This device compensates for temperature and signal errors, requiring minimal adjustment for reliable respiratory monitoring.

    Area of Science:

    • Biomedical Engineering
    • Respiratory Physiology

    Background:

    • Accurate measurement of respiratory volume is crucial for diagnosing and managing respiratory conditions.
    • Existing methods for respiratory flow integration can suffer from drift and errors due to environmental factors and signal imperfections.

    Purpose of the Study:

    • To design and evaluate an electronic circuit for precise integration of respiratory flow signals into volume signals.
    • To develop a robust integration circuit that minimizes errors caused by temperature fluctuations, baseline drift, and random noise.

    Main Methods:

    • A simple integrator circuit was designed, incorporating three specialized compensation subcircuits.
    • The subcircuits were engineered to counteract drift from ambient temperature changes, flow signal baseline errors, and random signal errors.

    Related Experiment Videos

  • A functional unit was constructed and tested to assess its performance and accuracy.
  • Main Results:

    • The designed circuit achieved integration errors typically below 1%.
    • The functional unit required only initial adjustment and no further calibration during sustained use.
    • The circuit demonstrated effectiveness in handling bidirectional respiratory flow signals within the human physiological frequency range.

    Conclusions:

    • The developed circuit provides a highly accurate and stable method for converting respiratory flow signals to volume signals.
    • This technology offers a reliable and low-maintenance solution for respiratory monitoring applications.
    • The circuit's performance meets the stringent requirements for clinical and research use in respiratory diagnostics.