Determination of picogram nitroglycerin plasma concentrations using capillary gas chromatography with on-column
Abstract:
A specific, sensitive, and precise capillary gas chromatographic (GC) assay capable of analyzing picogram concentrations of nitroglycerin in human plasma was developed. The analytical procedure involves a double extraction of 1 mL of plasma with pentane, after the addition of internal standard (1 ng of 2,6-dinitrotoluene), followed by evaporation and reconstitution in 50 microL of heptane. The extract (1 microL) was injected onto a capillary column using the on-column injection technique. The GC oven temperature was programmed from 120 degrees C to 180 degrees C at a rate of 5 degrees C/min. The oven temperature was then programmed to 250 degrees C and was maintained for 10 min. The nitroglycerin and internal standard retention times were 8.6 and 11.4 min, respectively. The position of the end of the capillary column inside the detector is a critical determinant of sensitivity: the column exit must be positioned such that nitroglycerin adsorption to the detector is minimized (i.e., sensitivity maximized). The assay limit of quantitation was 25 pg/mL (CV = 7.6%) using 1 mL of plasma. This GC assay, specific for nitroglycerin in the presence of its metabolites, isosorbide dinitrate, and several other drugs, may be used to quantitate plasma levels obtained after therapeutic nitroglycerin doses.
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a column.
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
Gas Chromatography: Sample Injection Systems
Two primary injection methods are used...
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography: Types of Detectors-II