Field comparison between two nitrous oxide (N2O) passive monitors and conventional sampling methods.

E C Bishop, M A Hossain

    American Industrial Hygiene Association Journal
    |December 1, 1984
    PubMed
    Summary

    A new Landauer NITROX passive monitor accurately measured nitrous oxide (N2O) levels in clinical settings. It performed better than other methods, offering reliable N2O monitoring for healthcare environments.

    Related Concept Videos

    You might also read

    Related Articles

    Articles linked to this work by shared authors, journal, and citation graph.

    Sort by
    Same author

    Post-partum Family Planning Practices Among Mothers Who Delivered in The Last 12 Months in Selected Areas of Gazipur.

    Mymensingh medical journal : MMJ·2026
    Same author

    Facial Basal Cell Carcinoma: Clinical Profile, Surgical Management and Outcomes.

    Mymensingh medical journal : MMJ·2026
    Same author

    Medial Plantar Artery Flap for Heel Reconstruction: A Retrospective Observational Study.

    Mymensingh medical journal : MMJ·2025
    Same author

    Knowledge, Attitude and Practice about Hepatitis C Virus Infection among the Health Care Workers in a Tertiary Care Hospital of Bangladesh.

    Mymensingh medical journal : MMJ·2025
    Same author

    Antibody Level against Hepatitis B Virus in Term and Preterm Infants Following Three Doses of Pentavalent Vaccine as per EPI Schedule.

    Mymensingh medical journal : MMJ·2025
    Same author

    Clinical Response of Paracetamol versus Indomethacin in the Medical Treatment of Patent Ductus Arteriosus in Newborn.

    Mymensingh medical journal : MMJ·2025

    Area of Science:

    • Environmental Health
    • Occupational Safety
    • Analytical Chemistry

    Background:

    • Nitrous oxide (N2O) is a common anesthetic gas used in medical and dental procedures.
    • Accurate monitoring of N2O exposure is crucial for patient and healthcare worker safety.
    • Existing monitoring methods may have limitations in accuracy or practicality in clinical settings.

    Purpose of the Study:

    • To evaluate the performance of a prototype Landauer NITROX passive monitor for N2O detection.
    • To compare the NITROX monitor's accuracy against established gas analysis methods.
    • To assess N2O monitoring capabilities in real-world clinical environments.

    Main Methods:

    • Field tests were conducted in hospital operating rooms, dental clinics, and veterinary clinics.

    Related Experiment Videos

  • Nitrous oxide concentrations ranged from 4 to 330 ppm.
  • The NITROX monitor was simultaneously tested against a Miran 1-A IR gas analyzer, a Solid State Sensor, and bag samples within a uniform real-time monitoring chamber.
  • Main Results:

    • The Landauer NITROX passive monitor demonstrated superior performance compared to the Solid State Sensor and bag samples.
    • The NITROX monitor showed favorable comparison with the Miran 1-A IR gas analyzer.
    • All tested methods were evaluated under conditions designed for uniform real-time monitoring.

    Conclusions:

    • The Landauer NITROX passive monitor is a promising tool for accurate N2O monitoring in clinical settings.
    • Its performance suggests it is a viable alternative to current monitoring techniques.
    • Further validation may confirm its utility for ensuring occupational safety regarding N2O exposure.