Related Experiment Video
Updated: Aug 14, 2026

Non-invasive Optical Imaging of the Lymphatic Vasculature of a Mouse
Published on: March 8, 2013
[Clinical evaluation of lymphoscintigraphy in urological disease]
Abstract:
Clinical efficacy of lymphoscintigraphy was evaluated in 31 cases of urological disease. To diagnose metastatic change of malignant tumor, 99mTc-rhenium colloid (5mCi) was administrated from bilateral pedal region. Of these patients 12 had true positive finding, 2 had false positive finding, 2 had false negative finding, and 8 had true negative finding defined by lymphoscintigram and pathological finding. Overall accuracy of lymphoscintigraphy revealed 83% in correlation of pathological finding, 78% in lymphangiography. Accuracy between lymphangiography and pathological finding was 80%. The overall clinical efficacy of lymphoscintigraphy was the same as lymphangiography. The merit of this method was that we can examine easily, painlessly, and frequently.
Related Concept Videos
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Imaging Studies II: Ultrasonography
Imaging Studies III: Computed Tomography
Imaging Studies V: Intravenous Urography and Retrograde Pyelography
Imaging Studies VI: Voiding Cystourethrography and Cystography
Urologic Endoscopic Procedure: Cystoscopic Examination