Related Experiment Video
Updated: Aug 2, 2026

Measuring Deformability and Red Cell Heterogeneity in Blood by Ektacytometry
Published on: January 12, 2018
A comparison of the erythrocyte sedimentation rate and plasma viscosity in detecting changes in plasma proteins
Abstract:
The Westergren erythrocyte sedimentation rate (ESR) and plasma viscosity were compared in 114 patients and their correlations with total and differential plasma protein fractions were analysed. There is a linear correlation between these two screening tests. Higher correlation coefficients were obtained between the plasma viscosity and fibrinogen and alpha and gamma globulins than with the ESR. Albumin affected the two tests in opposite directions. The ESR was falsely increased by a fall in haemoglobulin even within two standard deviations from the mean. Both tests gave an appreciable number of incorrect values--the plasma viscosity in 21 cases and the ESR in 33. The cause for these is discussed. It is concluded that the plasma viscosity is the more sensitive and reliable measure of changes in acute phase protein reactants and more useful for monitoring clinical progress.
More Related Videos
Related Concept Videos
SDS-PAGE
A variation of gel electrophoresis, termed polyacrylamide gel electrophoresis (PAGE), is commonly used for separating proteins according to their molecular size by passing them through a polyacrylamide gel. Because of the varying charges associated with amino acid side chains, PAGE can be used to separate intact proteins...